46
Address
Parameter
Name & Function
Default Unit
Setting
Range RS232 RS485
Speed command smooth accel/decel time Constant.
Sn206
Set Sn205=1 to enable this function then set the time period for
the speed to rise to 63.2% of the full speed.
1
msec
1
│
10000
52BH 0206H
Speed command linear accel/decel time constant.
Sn207
Set Sn205=2 to enable this function then set the time period for
the speed to rise linearly to full speed.
100
50
Ratio Speed
Speed Command (%)
Speed Command
Sn207
Time (ms)
1
msec
1
│
50000
52CH 0207H