48
Address
Parameter
Name & Functions
Default Unit
Setting
Range RS232 RS485
Speed loop Gain 2
Sn213
Refer to Sn211
40
Hz
10
│
450
53AH 020DH
Speed loop Integral time 2
Sn214
Refer to Sn212
100
x0.2
msec
1
│
500
53BH 020EH
Value of zero speed
Sn215
Set the zero speed range in Sn215
When the actual speed is lower than Sn215 value, Output
contact ZS is activated.
50
rpm
0
│
4500
532H 020FH
Analog Speed Command Ratio
Sn216
Slope of voltage command / Speed command can be adjusted.
10
5
-5
-10
Input
Voltage (V)
Slope set by
Sn216
4500
3000
1500
-4500
-3000
-1500
Speed Command
(rpm)
Rate rpm
rpm
/10V
100
│
4500
533H 0210H
Analog Speed Command offset adjust
Sn217
The offset amount can be adjusted by this parameter.
0
mV
-10000
│
10000
534H 0211H
Analog speed command limited
Sn218
Setting Sn218 for limit the highest speed command of analog
input.
Rate rpm
x 1.02
rpm
100
│
4500
C11H 0212H