65
Communication
Address
Parameter
Name & Function
Default Unit
Setting
Range
Control
Mode
RS232 RS485
DO-1 Functions
Setting
Explanation
Signal Functions
01
RDY Servo Ready
02
ALM Alarm
03
ZS
Zero Speed
04
BI
Brake Signal
05
INS In Speed
06
INP In Position
07
HOME HOME
08
INT In Torque
09
P1
Position Display 1 for Tool Turret mode
0A
P2
Position Display 2 for Tool Turret mode
0B
P3
Position Display 3 for Tool Turret mode
0C
P4
Position Display 4 for Tool Turret mode
0D
P5
Position Display 5 for Tool Turret mode
★
Hn613.0
Hn613.1
0E
P6
Position Display 6 for Tool Turret mode
Refer to
the cross
reference
table on
page 77.
X
01
│
0E
ALL
DO-1 Active Level
Setting
Explanation
0
Close, when the output is activated.
★
Hn613.2
1
Open, when the output is activated.
0
X
0
│
1
ALL
C47H 050DH
DO-2
★
Hn614
Plearse refer to Hn614
---
X
001
│
10E
ALL
C48H 050EH
DO-3
★
Hn615
Plearse refer to Hn614
---
X
001
│
10E
ALL
C49H 050FH
New setting will become effective after re-cycling the power.
Warning! If any of programmable Inputs of DI-1 ~ DI-13 are set for the same type of function
then the logic state selection ( NO or NC selection) for these inputs must be the same type.
Otherwise an Alarm will be displayed. AL-07 (Abnormal DI/DO programming).