N3 Drive Operations Manual
Appendix A- Product (Model) Specifications
A3
AA.2 Product (Model) Specifications
Single Phase, 200-240V
N 3 - 2 x x - C S
P 5
0 1
0 2
0 3
Horsepower(HP)
0 . 5
1
2
3
Max applicable motor output
(KW)
0 . 4
0 . 7 5
1 . 5
2 . 2
Rated output current(A)
3 . 1
4 . 5
7 . 5
1 0 . 5
Rated capacity(KVA)
1 . 2
1 . 7
2 . 9
4 . 0
Max. input voltage
Si n g l e P h a s e : 2 0 0 - 2 4 0 V +1 0 % - 1 5 % , 5 0 / 6 0 H
Z
5 %
Max. output voltage
T h r e e Ph a s e : 2 0 0 - 2 4 0 V
Input current(A)
8 . 5
1 2
1 6
2 3 . 9
Net weight Lb(KG)
2 . 8 7 ( 1 . 3 )
2 . 8 7 ( 1 . 3 )
3 . 3 1 ( 1 . 8 )
5 . 0 7 ( 2 . 3 )
Allowable momentary power
loss time (second)
1 . 0
1 . 0
2 . 0
2 . 0
Three Phase, 200
– 240V
N 3 - 2 x x - C / N 1
P 5
0 1
0 2
0 3
0 5
0 7
1 0
1 5
2 0
2 5
3 0 * 4 0 *
Horsepower(HP)
0 . 5
1
2
3
5
7 . 5
1 0
1 5
2 0
2 5
3 0
4 0
Max applicable motor output
(KW)
0 . 4 0 . 7 5 1 . 5
2 . 2
3 . 7 5 . 5
7 . 5
1 1
1 5 1 8 . 5 2 2
3 0
Rated output current(A)
3 . 1
4 . 5 7 . 5 1 0 . 5 1 7 . 5 2 6
3 5
4 8
6 4
8 0
9 6
1 3 0
Rated capacity(KVA)
1 . 2
1 . 7 2 . 9
4 . 0
6 . 7 9 . 9 1 3 . 3 2 0 . 6 2 7 . 4 3 4
4 1
5 4
Max. input voltage
T h r e e p h a s e : 2 0 0 - 2 4 0 V + 1 0 % - 1 5 % , 5 0 / 6 0 H
Z
5 %
Max. output voltage
T h r e e Ph a s e : 2 0 0 - 2 4 0 V
Input current(A)
4 . 5
6 . 5
1 1 1 2 . 5 2 0 . 5 3 3
4 2
5 7
7 0
8 5
1 0 8 1 3 8
Net weight Lb(KG)
2 . 6 5
( 1 . 2 )
2 . 6 5
( 1 . 2 )
2 . 6 5
( 1 . 2 )
3 . 8 5
( 1 . 7 5 )
4 . 1 9
( 1 . 9 )
1 2 . 3
( 5 . 6 )
1 2 . 3
( 5 . 6 )
3 3 . 1
( 1 5 )
3 3 . 1
( 1 5 )
3 3 . 1
( 1 5 )
7 2 . 8
( 3 3 )
7 5 . 0
( 3 4 )
Allowable momentary power
loss time (second)
1 . 0
1 . 0 2 . 0
2 . 0
2 . 0 2 . 0
2 . 0 2 . 0 2 . 0 2 . 0 2 . 0 2 . 0
Three Phase, 380
– 480V
N 3 - 4 x x - C / N 1
0 1
0 2
0 3
0 5
0 7
1 0
1 5
2 0
2 5
3 0 4 0 * 5 0 * 6 0 * 7 5 *
Horsepower(HP)
1
2
3
5
7 . 5
1 0
1 5
2 0
2 5
3 0
4 0
5 0
6 0
7 5
Max applicable motor output
(KW)
0 . 7 5 1 . 5 2 . 2 3 . 7 5 . 5 7 . 5
1 1
1 5 1 8 . 5 2 2
3 0
3 7
4 5
5 5
Rated output current(A)
2 . 3 3 . 8 5 . 2 8 . 8 1 3 . 0 1 7 . 5 2 5
3 2
4 0
4 8
6 4
8 0
9 6 1 2 8
Rated capacity(KVA)
1 . 7 2 . 9 4 . 0 6 . 7 9 . 9 1 3 . 3 1 9 . 1 2 7 . 4 3 4
4 1
5 4
6 8
8 2 1 1 0
C o n t .