N3 Drive Operations Manual
A (Advanced) Parameter Summary; A040
– A049
36
Cont
.
NOTES:
Parameter
No.
LCD Display
Description
Range/Code
Factory
Setting
Remarks
A040
Parameter
Copy
Copy Unit
0000: Disable
0001: Inverter to Copy Unit
0002: Copy Unit to Inverter
0003: Verify Copy Operation
0000
A041
Fan Control Fan Control
0000: Auto (Depend on drive
temperature.)
0001: Operate while in RUN mode
0002: Always Running
0003: Always Stopped
0000
A042
Energy Save
Mode
Energy Saving
Mode
0000: Disabled
0001: Controlled by MFIT
≠
at Set
Frequency
0000
6
A043
Energy Save
Gain
Energy Saving Gain
(%)
0 - 100
80
6
A044
Carrier Freq
Carrier Frequency
(kHz)
4 - 16
10
A045
Display Units
Custom Units (Line
Speed) Display
Mode
0000: Drive Output Frequency is
Displayed
0001: Line Speed is Displayed as an
Integer (xxxx)
0002: Line Speed is Displayed with
One Decimal Place (xxx.x)
0003: Line Speed is Displayed with
Two Decimal Places (xx.xx)
0004: Line Speed is Displayed with
Three Decimal Places (x.xxx)
0000
1
A046
Display Scaling
Custom Units (Line
Speed) Value
0 - 9999
1800
1
A047
A048
(Reserved)
A049
(AI2 Function)
AI2 Function Set
20 / 21 / 22
20
7