background image

Safety

Teco chillers are designed and built with safety as a prime consideration; industry-accepted 

safety factors have been used in the design. Each chiller is inspected at the factory for 
safety and operation. Any necessary adjustments are made before shipment. Follow 
the maintenance schedules outlined in this manual for optimum performance and safe 
operation. Any repairs should be done only by qualified personnel with proper training and 
tools. Carefully read all safety requirements before installation, operation or maintenance. 

The requirements are essential to ensure safe operation. Failure to follow these guidelines 

voids the warranty and may result in chiller damage or personal injury.

 

• 

Do not install or try to repair a chiller that has been damaged in shipment.  

See Receiving And Inspection for instructions.

 

Turn off and unplug the chiller before preforming any work. Electricity has the potential to 

• 

cause personal injury or equipment damage. 

 Do not operate the chiller at temperatures above the maximum ambient temperature (95˚F/35˚C) 

• 

 Always supply electrical power that complies with the voltage shown on the data label. 

• 

 Work on the refrigeration system must be done only by a licensed refrigeration technician. 

• 

Do not plug into wall socket without the housing in place.  

• 

Configure the electrical cord to include a “drip loop” - a loop section of chord that hangs 

• 

below the electrical outlet - this prevents water from reaching the outlet in the event of a leak.   

It is recommended that this product be used with a GFCI  

• 

(Ground Fault Circut Interrupter) outlet. 

Do not look directly at an illuminated UV light. (if installed) 

• 

Do not operate chiller without water flowing through it. 

• 

Never allow heater to be on without water flowing though the chiller. 

• 

Do not run pressurized water through chiller. Chillers are designed to accept water flow from

• 

recirculating pumps. Pressure pumps or high-pressure water lines will damage the chiller. If in 
doubt about your pump, contact the pump manufacturer. 

Summary of Contents for Seachill TR30

Page 1: ...SUPPLEMENTAL INSTRUCTIONS FOR TR30 TR60 HEATER INSTALLATION GUIDE ...

Page 2: ...s the potential to cause personal injury or equipment damage Do not operate the chiller at temperatures above the maximum ambient temperature 95 F 35 C Always supply electrical power that complies with the voltage shown on the data label Work on the refrigeration system must be done only by a licensed refrigeration technician Do not plug into wall socket without the housing in place Configure the ...

Page 3: ...Contact Us North American distributor TECO US Service service tecous com Sales sales tecous com www tecous com ...

Page 4: ...de housing about 2 8 20cm back Unplug green ground wire from housing Slide the 3 housing off Keep the plastic washers that come with the housing screws these prevent chipping of the housing powder coat Slide Housing completely off 4 Do not operate the chiller until housing is replaced STEP 1 ...

Page 5: ...g over the top of the Heater and push down 3 approximately 3 4 inch to 1 inch onto the Heater Insert Heater into heat exchanger until o ring seats into 4 outlet lip If you encounter resistance while inserting the Heater gently turn the Heater and apply very slight force Put ring nut over quartz sleeve and o ring Tighten to seal 5 Use channel lock pliers or similar to insure there is no leak 6 O RI...

Page 6: ...EATER INSTALLATION GUIDE STEP 3 Pull the heater plug through the hole in the frame 1 Connect two pin adapter on wiring harness to one of 2 the available two pin connectors mounted on top of support strut ...

Page 7: ... Remove jumper from pins 7 8 4 Now turn off your chiller 5 CAUTION Leaving chiller on with no water flowing will 6 cause the unit to overheat Place Jumper over pins 5 6 7 Note Resting your chiller will change your set temperature 8 to the default of 77 Re connect the green ground cable replace housing Your 9 Chiller s heater is now installed No Heater or UV Heater and UV Installed Heater Installed...