HEATER INSTALLATION GUIDE
STEP 4
Plug in and turn on the chiller
1
Find the circuit board on the top of the electronic housing.
2
Remove the plastic “jumper” from prongs 4 and 5 (See
Diagram Below).
Place jumper on pins 7&8, this will reset your chiller.
3
Remove jumper from pins 7&8.
4
Now turn off your chiller.
5
CAUTION: Leaving chiller on with no water flowing will
6
cause the unit to overheat.
Place Jumper over pins 5&6
7
Note: Resting your chiller will change your set temperature
8
to the default of 77.
Re-connect the green ground cable, replace housing. Your
9
Chiller’s heater is now installed.
No Heater or UV
Heater and UV Installed
Heater Installed
UV Installed
Heater
Jumper
Reset
Jumper
UV
Jumper