5.  MAINTENANCE 

This meter is a precise instrument. Any modificaDon to the circuit is not allowed. 
NOTE: 

i.

Don’t  input  the  voltage  value  higher  than 
600V DC or AC  rms. 

2) Don’t input voltage at current, resistance, diode or conDnuity range. 
3) Don’t  make  any  measurements  when  the  ba]ery  is  not  properly  installed  or  the 

back cover isn’t fixed. 

4) Before  replacing  ba]ery  or  fuse,  please  remove  the  test  leads  from  the  measuring 

point and turn off the power. 

5) Keep the meter away from water, dust and shock. 
6) Don't  expose  the  meter  under  high  temperature,  high  humidity,  combusDble, 

explosive and strong magneDc place. 

7) Wipe the case with a damp cloth and detergent. Do not use abrasives and alcohol to 

clean the meter. 

8) If  the  meter  will  not  be  used  for  a  long  Dme,  please  take  out  the  ba]ery  to  avoid 

leakage damage. 

9) When  “

”  symbol  is  displayed,  please  replace  the  ba]ery  according  to  the 

following steps: 

① Remove the holster at first. 
② Screw off the fixing screws of the ba]ery door and remove the cover; 
③ Take off the old ba]ery and replace with a new one. To extend the using life, it's 

be]er to use alkaline ba]ery. 

④ Fix the ba]ery door. 
⑤ Put on the holster. 

10) Fuse  replacement:  When  replacing  fuse,  please  use  fuse  with  same  type  and 

specificaDon. 

① Remove  the  holster  first,  then  screw  off  the  fixing  screws  of  the  ba]ery  door 

and back cover to remove the cover; 

② Take off the old fuse and replace with a new one. 
③ Install  the  back  cover,  then  fix  the  screws  of  the  ba]ery  door  and  back  cover. 

Put on the holster. 

6. Trouble Shoo5ng 

If the meter does not work properly, please check the meter as following steps: 
(If  the  problems  sDll  cannot  be  solved,  please  refer  to  repairing  center  or  contact  the 
local dealers.) 

The specificaDons are subject to changes without prior noDce; 

The content of this manual is regarded as correct. If users find out any mistakes or 
omissions, please kindly contact the manufacturer; 

The  manufacturer  will  not  be  responsible  for  accidents  and  damage  caused  by 
improper operaDons; 

The funcDons described in this User Manual shall not be considered as the reason 
for any special usages; 

Fatult

SoluDon

No reading on LCD

Turn on the power;

Release the HOLD key;

Replace battery.

Replace battery.

No input

Replace fuse.

Big error Value

Replace battery.

signal appears

Summary of Contents for DMM-136A

Page 1: ...ctric shock 2 4 Select correct funcDon and range to avoid wrong operaDon 2 5 Move the test leads away from test points when switching to other funcDon 2 6 Don t input voltage in current terminal 2 7 Don t make any modificaDon to the circuit It may damage the meter or jeopardize safety 2 8 Safety symbols High voltage GND Dual insulaDon Refer to manual Low ba ery indicaDon 3 Features 3 1 General Char...

Page 2: ...0 5A 250V fuse and 10A 250V fuse Frequency response 10A range 40 100Hz other ranges 40 400Hz 3 2 6 Resistance Ω Open circuit voltage 500mV Overload protecDon 250V DC AC peak value 3 2 7 Capacitance C Overload protecDon 250V DC AC peak value 3 2 8 Frequency Range Accuracy ResoluDon 600uA 1 0 5 0 1μA 6000uA 1μA 60mA 10μA 600mA 100μA 6A 1mA 10A 2 0 5 10mA Range Accuracy ResoluDon 600uA 1 5 5 0 1μA 60...

Page 3: ...is less than 50Ω buzzer sounds conDnuously Open circuit voltage 2 2V Range Accuracy ResoluDon 40 1000 400 1 0 5 400 1 5 15 1 0F 1832 750 1 0 5 750 1 5 15 Number Feature DescripDon 1 Relative REL mode is active 2 Data Hold is acDve 3 Indicates negaDve readings 4 DC DC voltage or current measurement 5 AC AC voltage or current measurement 6 AUTO Auto range mode 7 Null 8 Diode test mode 9 The conDnuit...

Page 4: ... be displayed Press HOLD again to exit the HOLD mode 2 Light Key Press HOLD key for more than 2 seconds to turn on the backlight The backlight can last for 15 seconds During 15 seconds press light key for 2 seconds again to turn off the backlight Non contact voltage detector area Holster Ba ery door See picture 4 2 DCV measurement 4 2 1 Insert the black test lead into COM terminal and the red one i...

Page 5: ... current is 600mA or 10A subject to which terminal the red test lead is inserted into Current exceeding rated value will damage the fuse and may cause damage to the circuit of meter 4 5 ACA measurement 4 5 1 Insert the black test lead into COM terminal and the red one into VΩmA terminal Max 200mA or into 10A terminal Max 10A 4 5 2 Turn the rotary switch to a proper current range Press SELECT key t...

Page 6: ...1 Even if there is no voltage indicaDon there may be voltage on the circuit Do not rely on NCV detector as the only way to detect voltage 2 Voltage detecDng may be affected by power socket design type of insulaDon and its thickness and other factors 3 Interference sources in the external environment such as flashing light motor would cause wrong signal to acDvate alarm funcDon 4 10 DIODE AND CONTINU...

Page 7: ...with a new one To extend the using life it s be er to use alkaline ba ery Fix the ba ery door Put on the holster 10 Fuse replacement When replacing fuse please use fuse with same type and specificaDon Remove the holster first then screw off the fixing screws of the ba ery door and back cover to remove the cover Take off the old fuse and replace with a new one Install the back cover then fix the screws o...

Reviews: