background image

P. 6

Tecshow Mini UV Bar |

English version

DMX address setting

Each fixture must set a specific starting address. 

When receiving signal transmission, fixture will 

receive channel control signals which from the 

starting address.

According to different requirements or easy to use, 

the user can set many value fixtures to the same 

address, also can set up a separate address for 

every device.

If you set the same address,all the devices will 

receive from DMX channels signal. All connecting 

fixtures are jointly controlled, controller can't sepa-

rate control a device.

If you set a different address, each device will be 

separate from its particular set the starting address 

and begin accepting DMX512 control signal, so that 

more convenient separate control one device. Using 

this method must be based on channel quantity of 

device to determine a starting address.

If led light has 2 channels.you should set the start-

ing address of the first unit to 1, the second unit to   

3 (2+1), the third unit to 5 (4+1), and so on.

Light 1 : address 1

Light 2: address 12         

Light 3: address 23

1.  The applicable temperature for the lighting is 

between -25°C to 40°C. Do not use the lighting 

under or above the temperature.

2.  The installation of the effect has to be built and 

constructed in a way that it can hold 10 times 

the weight for 1 hour without any harming 

deformation.

3. 

The installation must always be secured with a 

secondary safety attachment, e.g. an appropri-

ate safety rope.Never stand directly below the 

device when mounting, removing or servicing 

the fixture.

4. 

The operator has to make sure the safety re-

lating and machine technical installations are 

5. RINGING  

Mounting bracket

Hanging bracket 

Summary of Contents for MINI UV BAR

Page 1: ...P 1 Tecshow Mini UV Bar MINI UV BAR UV LED Bar 9 3W UV LEDs USER MANUAL MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCI NES ANTES DE USAR...

Page 2: ...ear dimmer of 0 100 strobe effect and can be controlled via DMX in addition to oper ating in automatic mode Specifications Source Optics Light Source 9 UV 3W LEDs LEDs life 50 000 hours Beam angle 150...

Page 3: ...rs as soon as possible The applicable temperature for the lighting is below 40 C Do not use the lighting above the temperature ta 40 C The fixture applicable widely it must keep ing clean Please do no...

Page 4: ...adjust different value press D enter LED digit display menu instruction The installation of the effect has to be built and constructed in a way that it can hold 10 times the weight and without any ha...

Page 5: ...F 8 DISP ON Display reverse ON OFF OFF Display reverse OFF 9 Fhrs XxxH Length of work 10 Ver Ver1 0 Software version 11 Defa Factory reset Value Function CH1 Dimmer 0 255 All LED dimmer 0 100 CH2 Stro...

Page 6: ...rate control one device Using this method must be based on channel quantity of device to determine a starting address If led light has 2 channels you should set the start ing address of the first unit...

Page 7: ...fore taking the device into operation for the first time 5 These installations have to be approved by a skilled person once a year 6 M8 screws on the mounting bracket which for fixed between hanging b...

Page 8: ...mally and lifetime service We won t provide warranty if the damage is caused by artificial or force ma jeasure event Please cut this warranty card and shipped it along with the product to our factory...

Page 9: ...mer lineal de 0 100 efecto estrobo y puede ser controlada v a DMX adem s de funcionar en modo autom tico Especificaciones Fuente ptica Fuente de luz 9 LEDs UV de 3W Vida til promedio 50 000 horas ngul...

Page 10: ...uirido el producto procure reti rarlo de su embalaje con cuidado Revise de tenidamente que no se haya da ado durante el env o En caso de que encuentre da os comun quese de inmediato con el fabricante...

Page 11: ...de seguridad durante la instalaci n Evite situarse debajo del equipo para realizar su montaje desmontaje o man tenimiento 3 PANEL DE CONTROL Instrucciones de uso Presione el bot n A para des plegar l...

Page 12: ...Rotaci n de pantalla encendida OFF OFF Rotaci n de pantalla apagada 9 Fhrs XxxH Tiempo de funcionamiento 10 Ver Ver1 0 Versi n de software 11 Defa Restablecer valores de f brica Valor Descripci n CH1...

Page 13: ...control DMX Para utilizar este m todo tenga en cuenta la cantidad de canales del equipo a la hora de determinar una direcci n de inicio Este equipo cuenta con 2 canales por lo cual la di recci n DMX...

Page 14: ...No mire de forma directa hacia la fuente de luz Las personas fotosensitivas o con epilep sia corren riesgo de sufrir convulsiones No mire en forma directa a la fuente de luz Las personas fotosensitiv...

Page 15: ...Los da os causados por ca das no est n sujetos a garant a Luego del a o de compra los costos de mantenimiento son responsabilidad del usuario Para hacer uso de la garant a corte esta tarjeta y env ela...

Page 16: ...P 16 Tecshow Mini UV Bar tecshow amproweb com...