Light will not come
on after power
failure
Some discharge lamps require a cooling off period,
before the electronics in the fixture can kick start
it again. Wait 5 to 10 minutes before the lamp is
cooled off and then power it up again.
■
Loss of signal
Use only proper DMX cables. Install a 120Ω termi
-
nator on the last device. Note: Keep DMX cables
separated from power cables or black lights.
■
■
■
■
Moves slow
Check the 220/110v switch for proper setting.
■
No flash
Re-install the bulb, it may have shifted during ship
-
ping.
■
No laser output
The bounce mirror motor may have shifted during
shipping, readjust it accordingly.
■
No light output
Install a new bulb. Fixture is too hot:
-Allow fixture to cool.
-Clean fan.
-Make sure air vents at control panel and front lens
are not blocked.
-Turn up the air conditioning The power supply
settings do not match local AC voltage and frequen
-
cy. Disconnect fixture. Check settings and correct if
necessary. Contact a technician for servicing, if the
problem persists.
■
Relay doesn’t work Check the reset switch. Check all cable connections.
■
Remote control
does not work
Make sure the connector is firmly connected to the
device.
■
■
Stand alone mode All Tecshow lighting fixtures featuring stand-alone
functions do not require additional settings, simply
power up the fixture and it will automatically enter
the stand-alone mode.
■