The fan must only be mounted / operated / maintained by skilled people. They must read the entire 
manual and it is as a minimum required that the regulations are followed. 
 
The fan must only be used for the purpose stated in the order agreement. 
 
If  the  fan  is  used  for  other  proposes  than  written  in  the  order  agreement,  if  the  construction  is 
changed, if the fan is not maintained as required in the check list or if there is used other spare parts 
than  the  original  one  the  prerequisites  fell  for  the  fans  stabile  operation  and  functionality  and  the 
guarantee will not be valid. The further use of the fan will be the user’s responsibility. 
 
The fan must 

not

 be mounted in an area there is classified as hazardous. 

 
This manual must be available near the fan in its lifetime. 
  
 
 

Warning 

 
Don’t do any cleaning, maintenance, repair, opening of bolted inspection openings or dismount of 
protection screen when the fan is in operation. 
 
All electrical power 

must be

 turned of on a save way when cleaning. 

 
The  fan 

must  not

  be  started  before  all  bolted  inspection  openings  and  screens  are  in  place.  All 

security devices must be in function before start up. 
 
Attention:  When  opening  the  fan  you  can  in  some  cases  open  to  an  atmosphere  classified  as 
hazardous. 
 
 
 
 
 
 
 

Summary of Contents for TMB-15/D-1400

Page 1: ...TECVENT A S Svallerup Bygade DK Kalundborg Tel Fax VAT No DK Reg No Jyske Bank e mail tecvent3tecvent dk www tecvent dk TECVENT TECVENT TECVENT TECVENT A S A S A S A S Manual for fan type TMB 15 D 1400 ...

Page 2: ...vent dk www tecvent dk Contents Terms of Use 3 Warning 3 Marking 4 Technical data 4 Description of the construction 5 Mounting 6 Mounting of the fan 6 Weight 7 Handling 7 Electrical connection 8 Potential equalization 8 Operation 9 General 11 Noise 11 Noise 11 Disposal 11 Spare parts parts list 12 ...

Page 3: ...the original one the prerequisites fell for the fans stabile operation and functionality and the guarantee will not be valid The further use of the fan will be the user s responsibility The fan must not be mounted in an area there is classified as hazardous This manual must be available near the fan in its lifetime Warning Don t do any cleaning maintenance repair opening of bolted inspection openi...

Page 4: ...mail tecvent3tecvent dk www tecvent dk Marking The name plate is located on the base frame of the fan The name plate will tell the producers name address technical data the year the fan is fabricated and the type Technical data Fan type TMB 15 D 1400 H 1 610 mm B 1 270 mm L 1 080 mm ...

Page 5: ...onstruction with reinforcements to secure against vibrations If the fan is with direct drive the fan impeller is mounted on the motor shaft If the fan is with belt drive the motor is located over or besides the fan shaft The fan impeller is fabricated in the type of steel required for the terms of use All impellers have been analyzed in a Finite Element System to prevent against stress related pro...

Page 6: ...ax 2 mm m When the machines are permanently set up the foundations must be correctly made in accordance with DIN 4024 Part 2 Before connecting the fan inlet and discharge make sure that no unwanted objects are located in the inlet or discharge channels and the fan itself The fan is constructed to deliver a discharge pressure above barometric pressure so make sure that the inlet channel can not be ...

Page 7: ...mail tecvent3tecvent dk www tecvent dk Weight Weight 370 kg Handling Al fans can be lifted by a forklift If a forklift is used lifting must take place under the fan If a crane is used to lift the fan all lifting points must be used It is not allowed to lift the fan trough the motor ...

Page 8: ...r rules in force at the country the fan is mounted Potential equalization There must be done potential equalization under rules in force at the country the fan is mounted The potential equalization must be done on fans for Zone 20 21 and 22 The cable must be mounted in the M10 hole under the bearing or the motor The potential equalization should also be done from the duct to the fan on both suctio...

Page 9: ...ction of rotation is right The arrow on the fan indicates the right direction of rotation Operation instruction If the fan is driven by a frequency converter When the fan speed is increased the fan needs power to accelerate besides the power normally used by the fan If the frequency converter gives a maximum current fault during acceleration then decrease acceleration to avoid the problem When the...

Page 10: ...enings and screens are in place All security devices must be in function before start up General The fan has reviewed a thorough assessment of the security After that a maintenance check list has been done The check list has to be completed signed and saved as documentation for the correct maintenance of the fan If the fan is not maintained as required in the check list or if there is used other s...

Page 11: ...ecvent dk www tecvent dk Noise The fan can contribute to the overall noise development If the overall noise development exceeds 80 dB A ear protection must be used Disposal When the fan is ready for disposal it must be de mounted and disposed under rules in force at the country the fan is mounted ...

Page 12: ...ade DK Kalundborg Tel Fax VAT No DK Reg No Jyske Bank e mail tecvent3tecvent dk www tecvent dk Spare parts parts list Only original spare parts must be used The specific spare parts are described on the spare parts list if any ...

Reviews: