Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

Form 5S4185

®

E

N
G

L

I

S

H

Printed in U.S.A.
09319
0501/091/VCPVP

Unpacking and Inspection

Handle with care. Check items received
against packing list to be sure that all
equipment has been received. Inspect
for shipping damage. If found, file
claim with carrier immediately.

IMPORTANT
SAFETY 
INSTRUCTIONS

Always follow basic safety
precautions with this equipment,
including the following:

To reduce the risk
of injury, do not

permit children to use this product
unless they are closely supervised at all
times.

This pump is for

use with

permanently installed pools and may
also be used with hot tubs and spas if so
marked. Do not use with storable pools.
A permanently installed pool is
constructed in or on the ground or in a
building such that it cannot be readily
disassembled for storage. A storable
pool is constructed so that it may be
readily disassembled for storage and
reassembled to its original integrity.

SAVE THESE
INSTRUCTIONS
READ AND
FOLLOW SAFETY
INSTRUCTIONS!

This is the safety alert symbol.

When you see this symbol on your

system or in this manual, look for one of
the following signal words and be alert
to the potential for personal injury.

Warns about

hazards that will

cause death, serious personal injury, or
major property damage if ignored.

Warns about

hazards that can

cause death, serious personal 
injury, or major property damage if
ignored.

Description

Teel all bronze, self priming pool/spa pumps, Model Numbers 4RH36, 4RH37,
4RH38, 4RH39, and 4RH40, with 5” integral trap, are for use with residential and
commercial swimming pools and spas. Maximum suction lift 10’. Models 4RH37,
4RH39, 4RH40 (3/4, 1, 1

1

2

, HP) are equipped with 115/230V capacitor start dual

voltage motors. Models 4RH38 and 4RH36 (2, and 2

1

2

HP) are equipped with 230V,

single voltage, capacitor start/capacitor run motors. These models deliver up to 100’
of head with capacities to 110 GPM. Motor coupled to impeller via adjustable stub
shaft.

4RH37

3/4

115/230/60/1

1

1

2

1

1

2

11

3

8

9

3

4

21

7

16

46 lbs.

4RH39

1

115/230/60/1

1

1

2

1

1

2

11

3

8

9

3

4

21

13

16

51

4RH40

1

1

2

115/230/60/1

1

1

2

1

1

2

11

3

8

9

3

4

22

15

16

57

4RH38

2

230/60/1

1

1

2

1

1

2

11

3

8

9

3

4

22

9

16

57

4RH36

2

1

2

230/60/1

1

1

2

1

1

2

11

3

8

9

3

4

23

1

2

67

Specifications

NPT

Motor

Suc.

Dis.

Dimensions

Model

HP

Volts/Hz/Ph

Inlet

Out

H

W

L

Wt

Performance Chart

4RH37

3/4

64

54

43

31

18

4RH39

1

66

58

49

40

29

16

4RH40

1

1

2

80

71

62

52

42

30

12

4RH38

2

*

88

78

69

58

47

33

4RH36

2

1

2

*

103

92

81

70

56

40

17

Model

Gallons Per Minute at Total Feet of Head

Number

HP

20’

30’

40’

50’

60’

70’

80’

90’

*Operating pump at or below this flow rate is not recommended and can cause motor to overheat.

Summary of Contents for 4RH36

Page 1: ...NS This is the safety alert symbol When you see this symbol on your system or in this manual look for one of the following signal words and be alert to the potential for personal injury Warns about ha...

Page 2: ...bration free To reduce vibration and pipe stress bolt pump to mount Allow pump suction inlet height to be as close to water level as possible Pump will not lift water more than 10 3m Allow use of shor...

Page 3: ...pump More than one pump can be connected to a single suction line as long as the requirements above are met WATER VELOCITY The maximum water velocity through any suction outlet must be 1 5 feet per se...

Page 4: ...r bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5...

Page 5: ...g 2 CLOSE GATE VALVES in suction and discharge pipes 3 RELEASE ALL PRESSURE from pump and piping system If pump is being pressure tested be sure pressure has been released before removing trap cover F...

Page 6: ...antifreeze RV antifreeze 5 Clean pump thoroughly replace trap cover 6 Be sure motor is kept dry and covered STARTUP FOR WINTERIZED EQUIPMENT 1 Remove any temporary weather protection placed around sy...

Page 7: ...o Figure 7 Page 8 for reference numbers 1 Loosen shaft extension Ref No 4A so it may be moved along the shaft with ease 2 Replace adapter Ref No 5 on motor and tighten capscrews Ref No 17 3 Make certa...

Page 8: ...s a day 365 days a year 8 1 4A 14 15 5 6 7 13 12 11 2 3 4B 16 16 9 10 17 Please provide following information Model number Serial number if any Part description and number as shown in parts list Addre...

Page 9: ...nd shall not exceed the purchase price paid WARRANTY DISCLAIMER Dayton has made a diligent effort to provide product information and illustrate the products in this literature accurately however such...

Page 10: ...ging Follow steps 1 through 7 under Removing Old Seal Page 7 Follow steps 7 through 11 under Installing a New Seal Page 7 for reassembly Worn Impeller and diffuser may be worn Order replacement parts...

Reviews: