33
5.2.6
Interleaved 2 Of 5
Enable/Disable Interleaved 2 Of 5
Enable Interleaved 2 Of 5 (Default)
Disable Interleaved 2 Of 5
Message Length
Message length can be set to the maximum value, minimum value. The data between the maximum and
the minimum is valid.
The maximum value and minimum value can be set using Programming Command. Please check the
programming command guide for the detail.
Interleaved 2 of 5 max length command: 020404. The parameter of this command can be set from min to
80.
Interleaved 2 of 5 min length command: 020403. The parameter of this command can be set from 2 to max.
Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25.
Programming command: Max: 02040425 ; Min: 02040310.
Interleaved 2 Of 5 Check Digit
No Check Char (Default)
Validate And Transmit
Validate Not Transmit
Summary of Contents for TMSL-60
Page 1: ...2D Barcode Reader User Guide V 1 2 1...
Page 18: ...17 Presentation Mode Reread Delay 3 10 Delay 500 MS Default Delay 750 MS Delay 1000 MS...
Page 19: ...18 4 Data Formatting General Configuration 4 1 Add CR Add LF Add CRLF Add TAB...
Page 60: ...59 Appendix 3 Digit Barcodes 6 3 0 1 2 3 4 5 6 7 8 9 A B C D E F...