38
5.2.10
Coda Bar
Enable/Disable Coda Bar
Enable Coda Bar (Default)
Disable Coda Bar
Message Length
Message length can be set to the maximum value, minimum value. The data between the maximum and
the minimum is valid.
The maximum value and minimum value can be set using Programming command. Please check the
programming command guide for the detail.
Coda bar max length command: 020206. The parameter of this command can be set from min to 60.
Coda bar min length command: 020205. The parameter of this command can be set from 2 to max.
Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25.
Programming command: Max: 02020625 ; Min: 02020510.