42
5.2.13
MSI
Enable/Disable MSI
Enable MSI
Disable MSI (Default)
Message Length
Message length can be set to the maximum value, minimum value. The data is valid between the
maximum and the minimum.
The maximum value and minimum value can be set using Programming command. Please check the
programming command guide for the detail.
MSI max length command: 020E04. The parameter of this command can be set from min to 48.
MSI min length command: 020E03. The parameter of this command can be set from 4 to max.
Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25.
Programming command: Max: 020E0425 ; Min: 020E0310.