1592006207 XB570L GB r1.1 26.08.2015
XB570L
19
18. TECHNICAL DATA
Housing:
self extinguishing ABS
Case:
frontal 185x38 mm; depth 70mm
Mounting:
panel mounting in a 150x31mm panel cut-out
Frontal protection:
IP65
Connections:
screw terminal block
≤
2.5mm
2
wiring
Power supply:
230Vac,
±
10%
Power absorption:
5VA max
Display:
dual display
Inputs:
5 PTC or NTC probes
Relay outputs:
Compressor:
relay SPST 20(8)A or 8(3) A, 250Vac
Defrost:
relay 8(3)A, 250Vac
Fans:
relay SPST 8(3)A, 250Vac
Light:
relay SPST 16(6)A, 250Vac
Aux1:
relay SPST 8(3)A, 250Vac
Aux2:
relay SPST 16(6)A, 250Vac
Serial output:
RS232 serial output for XB07PR printer connection
Serial output:
TTL serial output for monitoring system (MODBUS-RTU) protocol
Data storing:
on the non-volatile memory (EEPROM)
Data storage:
non-volatile memory (EEPROM)
Kinf of action:
1B
Pollution degree:
normal
Software class:
A
Operating temperature:
0 to 60°C (32 to 140°F)
Storage temperature:
-30 to 85°C (-22 to 185°F)
Relative humidity:
20 to 85% (no condensing)
Measuring range:
-55 to 50°C (-67 to 122°F)
NTC probe:
-40 to 110°C (-40 to 230°F)
PTC probe:
-50 to 150°C (-55 to 302°F)
Resolution:
0.1°C or 1°F (selectable).
Accuracy of the controller at 25°C:
±
0.3°C
±
1digit
19. STANDARD VALUE OF THE CYCLES.
Cy1: for fast chilling and conservation of foods at positive
temperature
CyS
= tEP
iS2
= 5°C (41°F)
Pd3
= OFF
dbC
= no
rS2
=-2°C (28°F)
dbH
= yes
iS1
= 20°C (68°F)
Pd2
= 2.0 h
HdS
= 3°C (37°F)
rS1
= -10°C (14°F)
iS3
= 3°C (37°F)
Pd1
= 2.0 h
rS3
=-2°C (28°F)
Cy2: for chilling and fast freezing of foods with holding
CyS
= tEP
iS2
= 5°C (41°F)
Pd3
= 2.0 h
dbC
= no
rS2
= -2°C (28°F)
dbH
= YES
iS1
= 10°C (50°F)
Pd2
= 2.0 h
HdS
=-18°C (0°F)
rS1
= -10°C (14°F)
iS3
=-18°C (0°F)
Pd1
= 2.0 h
rS3
=-30°C (-22°F)
Cy3: direct fast freezing with holding
CyS
= tEP
iS2
=-18°C (0°F)
Pd3
= OFF
dbC
= no
rS2
=-30°C(-22°F)
dbH
= yes
iS1
= -18°C (0°F)
Pd2
=OFF
HdS
= -18°C (0°F)
rS1
=-30°C (-22°F)
iS3
=-18°C (0°F)
Pd1
= 4.0
rS3
=-30°C (-22°F)
Summary of Contents for BLC10
Page 1: ...BLAST CHILLER FREEZER User Manual PT SL 49 61 EN FR IT ES 3 13 25 37...
Page 2: ...2...
Page 9: ...9 QUICK GUIDE For the daily use...
Page 13: ...REFROIDISSEURS CONG LATEURS RAPIDES Manuel d utilisation PT SL 49 61 FR IT ES 13 25 37...
Page 14: ...14...
Page 21: ...21 GUIDE RAPIDE Guide rapide quotidien...
Page 25: ...ABBATTITORI CONGELATORI Manuale d uso PT SL 49 61 IT ES 25 37...
Page 26: ...26...
Page 33: ...33 33 GUIDA RAPIDA Guida pratica quotidiana...
Page 37: ...ABATIDORES CONGELADORES Manual del usuario PT SL 49 61 ES 37...
Page 38: ...38...
Page 45: ...45 GU A R PIDA Gu a r pida diaria...
Page 49: ...PT SL 49 61 ABATEDORES DE TEMPERATURA CONGELADORES Manual do utilizador...
Page 50: ...50...
Page 57: ...57 GUIA R PIDO Guia r pido di rio...
Page 61: ...SL 61 HLADILNIK ZAMRZOVALNIKA ZA HITRO HLAJENJE ZAMRZOVANJE Navodila za uporabo...
Page 62: ...62...
Page 69: ...69 HITRI VODNIK Za dnevno uporabo...
Page 73: ...1592006207 XB570L GB r1 1 26 08 2015 XB570L 2 20 XB590L XB570L...
Page 94: ...1593006207 XB570L FR r1 0 26 08 2015 XB570L 2 24 XB590L XB570L...
Page 118: ...1591006207 XB570L IT r1 1 26 08 2015 XB570L 2 24 XB590L XB570L...
Page 141: ...1591006207 XB570L IT r1 1 26 08 2015 XB570L 25 24...
Page 142: ...1594006207 XB570L SP r1 0 26 08 2015 XB570L 2 20 XB590L XB570L...
Page 162: ...XB590L XB570L...
Page 177: ...1592006207 XB570L GB r1 1 26 08 2015 XB570L 16 20 3 12 2 MONTAGEM...
Page 184: ...1592006207 XB570L GB r1 1 26 08 2015 XB570L 2 20 XB590L XB570L...