STEP 8
Begin and complete the second row of
FLAT-
5XL SOLAR tiles
, completing the fixings and
connections in accordance with steps 1, 2, 3,
4, 5 and 6. In this example, a string is made
up of two rows of
SOLAR FLAT-5XL tiles
.
In this case, the negative terminal of the first
solar tile in the second row is connected to
the positive terminal of the first tile in the string,
which is the first solar tile in the previous row.
The positive terminal is connected to the next
adjacent solar tile in the same row.
STEP 9
Finish the left side of the roof by installing
a FLAT-5XL ceramic tile and left FLAT-5XL
edge piece, as detailed in step 6.
The positive terminal of the last tile in the string
is connected to the corresponding MC4
splitter cable for the parallel connection,
placing the cable underneath the second
batten.
26