8. Lock Control Wiring
Figure below shows the loca on and the Pin connec ons for door lock.
Electronic lock pin connec on instruc ons are as below:
1. For normally open (NO) electromagne c locks, connect J1 ① and ② (The ② is for the
public GND).
2. For normally closed (NC) electromagne c locks, connect J1 ③ and ② (The ② is for the
public GND).
3. For normally open (NO) door unlock bu on or alarm input device, connect J1 ④ and ⑤.
Rev 1.0
6 | P a g e
Tejovat Technologies
DP1000 User Manual