5.4. Connecting the compressed air supply
NOTICE
The compressed air must be dry and oil-free.
According to ISO 8573-1:2010 the compressed air quality must at least meet: [7:4:4]
➔
Partikle size: <40µm
➔
Pressure dew point: <= +3°C
➔
Oil content: <=5mg/m³
5.4.1. Compressed air supply for the cleaning of the filter cartridges
This section is only relevant if the system is equipped with the optional automatic cleaning
mechanism.
Cleaning is carried out pneumatically via a built-in compressed air tank.
Without compressed air supply the filter cartridges will become dirty very quickly.
●
The external compressed air supply must be assured with an approved compressed air hose.
For the connection to the device, the compressed air hose must be equipped with a quick
coupling for an insert sleeve DN 7.2.
The compressed air must be dry and oil-free.
●
The operating pressure of the compressed air supply must be a minimum of 1,5 bars and
maximum of 2,0 bars.
In case of the pressure being too low, the compressed air tank does not reach
quickly enough the operating pressure for the following cleaning. There is a risk of
material damage when the pressure is too high.
●
Connect the compressed air hose to the insert sleeve (see chapter 2.1).
6. Operating the system
6.1. Explanation of the operating elements
Control functions, setting options for programs, menu navigation, error messages, etc. are
described in the enclosed operating manual of the unit control. There is also an explanation of the
elements of the control panel.
BA_Handycart-DC_200529_EN
11
11.01.2022