1.Do not install the cooker hood where there are many doors or windows,
to avoid effecting the exhaust efficiency of the hood caused by air
convection.(Fig. 1)
2.Install the cooker hood right above the hob. The recommended
distance between the hob and the lower edge of the cooker hood show as
below. (Fig. 2)
3.To obtain optimum performance, the external conduct must not be more
than FOUR METRES long, have no more than two 90° angles and its
diameter must be at least
Ø
120. (Fig. 3)
4.After hanging the unit on the wall, ensure the hood is level and vertical.
5.The air outlet must not be connected to chimney flues or combustion
gas ducts. The air outlet must under no circumstances be connected to
ventilation ducts for room in which fuel-burning appliances are installed.
Outer duct cover
Exhaust pipe
Blower box
Hook
Inner duct cover
Air outlet
Exhaust pipe
Blower box
Inner duct cover
Air outlet
Outer duct cover
Hook
4
DVC560B
DVC560W
DVU560B/DVU560W
DVU590B/DVU590W
Fig.2
Fig.3
Fig.1
400~450mm
MAIN PARTS NAME
INSTALLATION REQUIREMENTS