11

Before installing the hood, consult the require-
ments of the corresponding authorities concer-
ning air and smoke extraction regulations.

Extracted air must not be channelled through
ducts used for exhaust fumes from appliances
powered by any form of energy other than elec-
tricity.

The room (kitchen) must be well ventilated if
the extractor hood is to be used at the same
time as other extractor fans or other applian-
ces powered by any form of energy other than
electricity.

When the hood is to operate at the same time
as other appliances powered by any form of
energy other than electricity, the air output
pressure must not be more than 4 Pa (4 x 10

-5

bar).

To  ensure optimum hood performance, the
length of the venting duct should not exceed
FOUR metres and should not have more than
two right angles (90º).

If the hood is supplied without a lead for
mains connection (or if this is replaced), it
must be disconnected from the mains by
means of an omnipolar cut-off switch, with a
minimum contact separation of 3 mm at all
the poles, incorporated into the fixed installa-
tion.

The appliance must be connected to the
mains using flexible cable. Rigid tubing should
not be used.

Using the screws provided in the accessory
bag, bolt the hood to a wooden panel in which
the fitting opening has previously been cut.

The bottom of the hood must be positioned at
a minimum height of 65 cm above electric
hobs and 70 cm in the case of gas hobs. If
gas hob installation instructions indicate a
greater distance, this must be taken into
account.

Installation

Technical Information

10

Dimensions

Fitting Dimensions

(mm)

(mm)

500 x 320 x 295

455 x 300

(Width x Depth x Height)

(Width x Depth)

MOD.
TYP.

ELECT.

220...230 V ~ 

50 Hz

330 W

Made in European Community- C.I.F.: A-39004932

GF-T

P-521325

Nº. de fabric.
Fabrík.-Nr.
Serial Nº

24-000001

h

Electrical characteristics: SEE RATING LABEL

Positioning in cabinet

455

300

POTENCIA NOM. LÁMPARAS
NENLEISTUNG GLÜHLAMPEN
LAMPS RATE
PUISSANCE LAMPES

2 X 40 W

POTENCIA NOM. DAS LAMPADAS

Summary of Contents for GF-T

Page 1: ......

Page 2: ...ructions Do not use the hood if the power cable has been damaged in any way or if the control swit ches shows visible signs of deterioration If the hood stops working or operates abnor mally disconnect its power supply unplug from the mains and get in touch with your TEKA Technical Service Do not leave uncovered gas rings burning under the hood Do not allow grease to accumulate on any part of the ...

Page 3: ...n 4 Third speed maximum This is independent of the extractor fan motor thus allowing the hob lighting to be used irres pective of the extractor hood s operating status On Off 5 Fan motors Light switch Special Requirements before First Use Using your Hood Your cooker hood is equipped with A Sliding three speed extractor fan control B Light switch for illumination with or wit hout fan operation C On...

Page 4: ...d greases Special cleaning sprays can also be used taking care to protect non meta llic parts After cleaning allow the filter to dry N B Cleaning the filter in a dishwasher with strong detergents may blacken its metal surfa ce without affecting its grease retention capa city Warning Filters must be cleaned at least once a month depending on hood usage Grease will accumulate on the hood and in the ...

Page 5: ... is 40 W 8 Changing light bulbs Fault Possible Cause Solution Hood does not work Mains cable not connected Connect mains cable Power not reaching plug Check repair mains supply Hood not extracting sufficiently or vibrating Filter saturated with grease Clean or replace filter Obstruction in venting duct Remove obstruction Inadequate venting duct Contact installer and follow the instructions in this...

Page 6: ...t must be disconnected from the mains by means of an omnipolar cut off switch with a minimum contact separation of 3 mm at all the poles incorporated into the fixed installa tion The appliance must be connected to the mains using flexible cable Rigid tubing should not be used Using the screws provided in the accessory bag bolt the hood to a wooden panel in which the fitting opening has previously ...

Page 7: ...The mains power cable may only be replaced by qualified technical service personnel 12 Replacement of mains power cable 455 500 300 320 87 Ø 158 ...

Page 8: ...57 TEKA PRODUCTS UK LTD Abingdon U K 44 1235 86 19 16 1235 83 21 37 TEKA TEKNIK MUTFAK A S Istanbul TURKEY 90 212 274 61 04 212 274 56 86 MARMICOC S A Rio de Janeiro BRASIL 55 21 671 01 88 21 772 16 37 TEKA CHILE LTDA Santiago de Chile CHILE 56 2 273 34 68 2 273 10 88 TEKA MEXICANA S A DE C V Mexico D F MEXICO 52 5 762 04 90 5 762 05 17 P T TEKA BUANA Jakarta INDONESIA 62 21 39052 74 21 39052 79 T...

Reviews: