18
EN
This fixation will be made from the inside part of
the cooker hood, after disassembling the filters.
In order to assemble the frame again once the
hood is installed, you will proceed in the inverse
way.
c)
To the internal laterals of the furniture through
floating holes
denominated “C”, wich exist in each
side of the body hood. This fixation will be made
from the inside part of the cooker hood, after
disassembling the filters.
The lower part of the extractor must be located at
a minimum height of 50 cm above the hob for
electric cookers and 65 cm for gas cookers. If the
instructions of a gas cooker indicate a
greater
distance these must be observed.
To achieve optimum performance the length of
the outlet hose should not exceed 4 meters, or
include more than two 90º angles (elbows).
Although venting to the outside is recommended,
activated carbon filters may be used, which allow
the gas to be returned to the kitchen through the
outlet pipe.
If something does not work
Before seeking technical assistance carry out the
following checks first:
DEFECT
POSSIBLE CAUSE
SOLUTION
The extractor does
not work
The cable is not connected
Connect the mains cable
No current is reaching the
plug
Revise/repair the electricity circuit
The extractor does
not blow enough or
vibrates
Filter saturated with grease
Clean or substitute the filter
Outlet obstructed
Eliminate obstructions
Inadequate air conduit
Contact the installer and follow
instructions of this manual
The lamps do not
light
Lamp broken
Contact the Customer Service
ILCOS D Code: DBR-1,5-H-67
Special U.K. Requirements
Height above gas hob: 75 mm minimum.
NEVER PLACE THE COOKER HOOD OVER AN
EYE-LEVEL GRILL.
This appliance must be connectec by a
competent person, using fixed wiring via a
DOUBLE POLE SWITCHED FUSED SPUR
OUTLET.
Special Australia Requirements
This appliance is not intended for use by young
children or infirm persons without supervision.
Young children should be supervised to ensure
that they do not play with the appliance.
Electrical connection
We recommend that the appliance is connected
by a qualified electrician, who is a member of the
N.I.C.E.I.C. and who will comply with the I.E.E.
and local regulations.
Should the colour of the wires in the mains lead
for the appliance not correspond with the
coloured markings identifying the terminal in your
spur box proceed as follows:
•
The wire which is coloured blur must be
connected to the marked
N
(Neutral) or
coloured Black.
•
The wire which is coloured brown must be
connected to the marked
L
(Live) or
couloured Red
•
Where avialable (see installation), the wire
which is coloured yellow/green must be
connected to the market
⊥
or coloured
Yellow/Green.
If the cooker hood is installed for use above a
gas appliance then the provision vor ventilation
must be in accordance with the Gas Safety
(Installation & Use) Regulations 1984 and the
relevant
Building
Regulations.
Detailed
recommendations are contained in the following
British Standard Codes of Practice BS6172,
BS5440 and BS6891 Current Edition.