background image

14

ENG 

Dear client:

Congratulations on your choice. We are sure
that this  modern, functional and practical
appliance, made with top quality materials,
will fully satisfy your needs.

Please read every section of this
INSTRUCTIONS MANUAL before using your
kitchen hood for the first time, to ensure
maximum performance from the appliance
and to avoid breakdowns, which may be
caused by  incorrect use, as well as to allow
any minor problems to be solved.

Store this manual, as it will provide useful
information about your kitchen hood at all
times and will also help other people to use it.

• Please be aware of current local

regulations with reference to domestic
electrical fittings and gas eduction.

• Verify that the tension and frequency of the

network match those indicated on the label
located inside the kitchen hood.

• The appliance must be connected to the

network using a break switch with a
universal cut off and minimum contact
separation of 3 mm.

• Once the kitchen hood has been installed,

ensure that the mains cable to the network
is not in contact with any live metal edges.

• Avoid connecting the appliance to

conductors used as exits for fumes
produced by a non-electric energy source,
e.g.: boilers, chimneys, etc.

• If the extractor fan is going to be used

simultaneously with equipment powered by
a non-electric energy source, e.g.:  gas
cookers, then the room must have
sufficient ventilation.

• Excessive fat accumulation in the kitchen

hood and metal filters is a fire risk and may
also cause dripping, therefore the inside of
the kitchen hood and the metal filters must
be cleaned at least once a month.

• The lower part of the kitchen hood must be

fitted at least 50 cm. over electric hobs and
65 cm. over gas or mixed hobs.

• Never leave gas hobs lit if not covered by a

container. The fat accumulated in the filters
may drip or catch fire when the
temperature increases.  

• Avoid cooking under the kitchen hood if the

metal filters are not fitted, e.g.: while they
are being cleaned in the dishwasher.

• You must not produce flames under the

kitchen hood.

• Disconnect the appliance before any

interior manipulation. E.g. during cleaning
or maintenance.

• We recommend the use of gloves and to

be extremely careful when cleaning the
kitchen hood's interior.

• Your kitchen hood is designed for domestic

use and only for extraction and purification
of fumes produced during food
preparation. It will be your responsibility if it
is used for other purposes, which may be
dangerous. The manufacturer cannot
accept responsibility for damage caused
by improper use of the appliance.

• For repairs please contact the nearest

TEKA Technical Assistance Service, and
always use genuine spare parts. Repairs
or modifications carried out by unqualified
personnel can cause malfunctions or may
damage the appliance, putting  your safety
in danger.

Safety Instructions

Manual ND.qxd  12/01/2005  17:10  Page 14

Summary of Contents for Kitchen hood

Page 1: ...ampanas Extractoras ND 3 Bedienungsanleitung Dunstabzugshauben ND 3 Instructions Manual Kitchen Hoods ND 3 Manuel d instructions Hottes aspirantes ND 3 Manual de Instruções Exaustores ND 3 Manual ND qxd 12 01 2005 17 10 Page 1 ...

Page 2: ...s cookers then the room must have sufficient ventilation Excessive fat accumulation in the kitchen hood and metal filters is a fire risk and may also cause dripping therefore the inside of the kitchen hood and the metal filters must be cleaned at least once a month The lower part of the kitchen hood must be fitted at least 50 cm over electric hobs and 65 cm over gas or mixed hobs Never leave gas h...

Page 3: ... the extractor fan to run for several minutes after you have finished cooking between 3 to 5 minutes in order to expel all the grease from the outlet duct This prevents the return of grease smoke and smells 1 The draft hood will remain on for 10 minutes at the selected level if pressed at any speed for more than 2 seconds To programme a time other than the pre selected one 10 minutes a Press the T...

Page 4: ... will not affect its fat retention capacity Once clean leave them to dry off and then fit them onto the kitchen hood Proceed as follows Unscrew the lamp cap trimming cover Change the broken burnt out lamp Maximum lamp power is 20 W G 4 Screw in the lamp cap trimming cover Cleaning and maintenance _________________________________________________________ Problem solving Proceed with the following c...

Page 5: ...twork tension V Network frequency Hz Lights Motor power W Extraction capacity 214321ND 220 240 50 2x20 250 800 m3 h 216321ND 220 240 50 2x20 150 600 m3 h 234321ND 110 127 60 2x20 280 730 m3 h TEKA INDUSTRIAL S A reserves the right to make changes and corrections to its products as it deems necessary without altering their basic characteristics Manual ND qxd 12 01 2005 17 10 Page 17 ...

Page 6: ...t H as per the detail in figure 1 Lift the upper tubecover up to the desired height and mark its shape on the wall Remove the tubecovers 10 Fit the clips F to the support C 11 Centre the support C around the shape marked trace and drill the fixing points for the wall plugs E Ø6 x 30 Attach the support C with the long bolts D Ø4 x 30 12 Fit the part A if the inner tube not supplied is Ø150 or A B i...

Page 7: ...19 ENG FIG 1 FIG 2 Manual ND qxd 12 01 2005 17 10 Page 19 ...