1.
The user Enables ClearPath. (Enabling energizes the motor
coils and puts ClearPath in Manual Homing mode.)
2.
The motor remains stationary until the user's control system
issues a move toward the Physical Home (hard stop) using
Step & Direction or Pulse Burst signals.
Note: This initial
move must be long enough to guarantee the load will hit the
hard stop from the farthest point away from the stop.
3.
The load hits the hard stop, triggering the Hard Stop Detection
algorithm. Holding torque against the hard stop is
automatically rolled back.
4.
If the motor's HLFB output is set to "ASG", the output asserts.
5.
ClearPath waits for the user's controller to send pulses to
command motion
away
from the hard stop. Any further
commands into the hardstop are disregarded while the motor
is folding back torque.
6.
Upon seeing the first step or pulse away from the hard stop
ClearPath's position counter is automatically zeroed. ClearPath
exits homing mode and is ready for further move commands.