A
PPENDIX
E:
24VDC
S
UPPLY
W
IRING
1
2
5
3
9
6
7
8
4
PE
PE
Wired for
power supply off
during a safety
event only
Wired for
power supply off
when machine
is shut off
Belden/9314 (14 AWG, 2 cond, 300V, shielded)
24VDC
OUTPUT
A
C IN
A
C IN
24VDC
OUTPUT
Belden/9314
20 Amp
External 24 VDC
Power Supply
10 Amp
External 24 VDC
Power Supply
AC LINE 1
AC LINE 2
24VDC (CKTS. 2 AND 3)
24VDC RETURN
(CKTS. 2 AND 3)
24VDC (CKT.1)
PE
AC LINE 2
AC LINE 1
24VDC RETURN (CKT.1)
18 AWG
twisted pair
14 AWG
twisted pair
eF-785
MAIN HAZARD
POWER
AC CONTROL
POWER
IMPORTANT:
Label this cable and power supply:
"LIVE HAZARDOUS AC WHEN INTERLOCKS
ARE OPEN OR HAZARDS ARE OFF"
CONNECTOR J5
9 POS. PLUG
AMP P/N 350720-1
PIN TERMINALS
AMP/350547-3
24VDC Supply Connections for 20A supply feeding 24VDC Circuits 2 and 3 (power supply
off during a safety event), and 10A supply feeding 24VDC Circuit 1 (power supply off when
machine is shut-off)
1
2
5
3
9
6
7
8
4
PE
PE
Wired for
power supply off
during a safety
event only
Wired for
power supply off
when machine
is shut off
Belden/9314
14 AWG, 2 cond,
300V, shielded
24VDC
OUTPUT
24VDC
OUTPUT
A
C IN
A
C IN
Belden/9314
10 Amp
External 24 VDC
Power Supply
20 Amp
External 24 VDC
Power Supply
AC LINE 1
AC LINE 2
24VDC (CKTS. 2 AND 3)
24VDC RETURN
(CKTS. 2 AND 3)
24VDC (CKT.1)
PE
AC LINE 2
AC LINE 1
24VDC RETURN (CKT.1)
14 AWG
twisted pair
18 AWG
twisted pair
eF-785
MAIN HAZARD
POWER
AC CONTROL
POWER
IMPORTANT:
Label this cable and power supply:
"LIVE HAZARDOUS AC WHEN INTERLOCKS
ARE OPEN OR HAZARDS ARE OFF"
CONNECTOR J5
9 POS. PLUG
AMP P/N 350720-1
PIN TERMINALS
AMP/350547-3
24VDC Supply Connections for 10A supply feeding 24VDC Circuit 1 (power supply off
during a safety event), and 20A supply feeding 24VDC Circuits 2 & 3 (power supply off
when machine is shut-off
)
e F - 7 8 5
I
N S T A L L A T I O N
M
A N U A L
83
T
EKNIC
,
I
NC
F
AX
(585)784-7460
V
OICE
(585)784-7454
Summary of Contents for EF-785
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Page 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Page 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Page 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Page 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Page 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Page 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Page 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Page 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...