background image

Short press “Learn/Erase” button on RC to activate pairing mode, and the 

receiver unit will flash once every second for 3min.

Note: the unit can only pair up to 30 units.    

St

ep

1

The receiver unit (slave unit)

Red LED indicator is on for 3min

 

 

Short press “Learn

/Erase” button

St

ep

3

The receiver unit (slave unit)

 

Red LED indicatoron in on

 

Erase:

Long press “Learn/Erase” button for 3s to the sensor unit. The 

red LED indicator 

rapidly flash for about 5s. all commands it has received before will be erased.

 

 

 

 

 

 

 

 

St

ep

2

The commander unit (master unit)

 The red LED indicator flash one time.

 

 

The red LED indicator flash rapidly

 

when RF signal is received

 

 

  

Short press “Transmit” button on RC, the commander unit (master unit) will 

flash one time to send the transmission signal.  

Upon receiving the transmission signal, the receiver unit (slave unit) will 

rapidly flash 3 times in 1s to indicate the success of pairing. Repeat this step 

to pair more units. One more short press on “Learn/Erase” button to the 

receiver unit to complete the pairing process, the receiver unit will quit the 

pairing mode. 

Note:

Press button RX100%, the light on receiver unit is 100% on upon receiving 

RF on signal; Press “RX STBY%” button, the light(s) goes to preset stand-by 

dimming level directly.`

The receiver unit (slave unit)

Short press “Transmit”

button

Short press “Transmit”

button

RF GROUPING

 

MALFUNCTION CAUSE REMEDY

CAUSE

REMEDY

The fixture does not light up

The fixture is always on

The fixture is on when it should not

Adjust zone, change installation site

Incorrect daylight threshold setting

Continous movement in the detection zone 

Sudden change in temperature due to weather (wind, 

rain, snow) or air expelled from fans, or open windows

Faulty fixture
No power supply

Adjust daylight threshold setting
Replace fixture
Check power to sensor
Check detection area setting

SECTION 3: TROUBLESHOOTING

1. 

Minimum distance from luminaire to any flammable object is 2m.

2. 

In case of weight discrepancy when replacing old lamps, please ensure that the mounting structure is rated to 

withstand the weight of the new lamp and installation materials. 

3. 

For further information, please contact Teknik (www.tekniklighting.com.au) or your local distributors.

NOTES

Summary of Contents for SMARTBAY One Box

Page 1: ...APPROVED VEET IPART APPROVED SMARTBAY ONE BOX LED HIGHBAY USER MANUAL Teknik Lighting Solutions Pty Ltd ABN 44 608 397 913 Tel 1300 313 780 www tekniklighting com au ...

Page 2: ...e with these instructions and relevant Australian Standards 5 Instant restart is allowed 6 Do not change or tamper with any internal electric circuits add any wires connectors or cables for any reason 7 Please do not insert any physical objects of any nature into the fitting as this may cause electric shock malfunction or damage to the products 8 Before replacement of the fitting turn the power of...

Page 3: ...ook Mount Bracket Mount Optional Note Supplied safety lanyard should be used for all installation options INSTALLATION DIAGRAM 150mm 150mm 500mm CHAIN iron load capacity 30kg M8 b a 9 6 6 42 120 9 e c d ...

Page 4: ...ensor module is fitted and use sensor option switches as below When non sensor option is required ensure blanking module is fitted and use non sensor switches as below ON ON ON ON ON ON 80W 80W SENSOR NO SENSOR 120W 150W 175W Sensor Version No Sensor Version 150W 200W 120W 175W Sensor Wattage DIM 12V GND OFF OFF OFF OFF OFF OFF 1 1 1 1 1 1 1 2 2 2 2 2 2 3 3 3 3 3 3 4 4 4 4 4 4 2 ...

Page 5: ...e 30s 30min Daylight Sensor 2 500Lux Disable Stand by Period 0s 10s 1h Stand by Dimming Level 10 50 Mounting Indoors ceiling wall mounted Working Temperature 20 60o C Model HS SEN Microwave constant illumination HS SEN RF Microwave constant illumination RF 868MHz Detection Range DXH 100 Hold Time 20mins Daylight Sensor 500Lux Stand by Period Stand by Dimming Level 30 Note When sensor option is not...

Page 6: ...ed standby dimming level If no motion is detected during the standby time the SMARTBAY will switch to power saver mode 10 light output The SMARTBAY will remain in power saver mode 10 light output if the ambient light level is above the daylight threshold When no movement is detected after the selected hold time light will dim to the selected standby level When the ambient light level is below the ...

Page 7: ...sfully 1 3 7 9 6 8 10 11 13 14 12 2 4 5 HS REM A 4h h 4h Permanent ON OFF button Press button to select permanent ON or permanent OFF mode 1 1 Press button to resume automatic operation The mode will change to AUTO Mode after power failure or circuit power is cycled via switch or breaker 2 4 Note Off activates power saver mode 10 light output Note the red LED indicator will flash once when RC rece...

Page 8: ......

Page 9: ...o complete the pairing process the receiver unit will quit the pairing mode Note Press button RX100 the light on receiver unit is 100 on upon receiving RF on signal Press RX STBY button the light s goes to preset stand by dimming level directly The receiver unit slave unit Short press Transmit button Short press Transmit button RF GROUPING MALFUNCTION CAUSE REMEDY CAUSE REMEDY The fixture does not...

Page 10: ...d or corrosive areas 4 Electrical installations periodically receive transient over voltages This product has been designed to minimise the effect of such voltages on connected equipment It may not give full protection for extreme over voltage transients such as those resulting from a close lightning strike 5 This product utilises intellectual property in the form of registered designs trademarks ...

Reviews: