TEK-CPCI-1003 Technical Reference Manual
8-8
8.4.3 Thermal Management
The thermal management is built around two digital temperature sensors and a thermal
watchdog. Both devices can be programmed to set their outputs when the temperature of
the processor or the ambient temperature exceeds a programmable high limit, and reset its
output when the temperature is under a programmable low limit. A special routine is
implemented to throttle the CPU clock until the temperature falls below the programmed
low limit.
Please refer to Section 12.3.5 –
Thermal Management Setup
for a complete information
thermal management setups.
Summary of Contents for TEK-CPCI 1003
Page 15: ...TEK CPCI 1003 Technical Reference Manual 5 4 5 1 CONNECTOR LOCATION...
Page 22: ...FEATURE DESCRIPTION 7 ONBOARD FEATURES...
Page 51: ...TEK CPCI 1003 Technical Reference Manual 9 2 JUMPER LOCATION...
Page 52: ...Setting Jumpers 9 3 JUMPER SETTINGS Table 1...
Page 53: ...TEK CPCI 1003 Technical Reference Manual 9 4 JUMPER SETTINGS TABLE 2...
Page 67: ...SOFTWARE SETUPS 12 AWARD SETUP PROGRAM 13 UPDATING THE BIOS WITH UPGBIOS 14 VT100 MODE...
Page 95: ...C 1 C BOARD DIAGRAMS C 1 ASSEMBLY TOP DIAGRAM...