6-v6_4_en
2
6 Information Capacity
Table 1
– Events and notifications to indicator and relay
Event type
Indicator
Relay
Starting of
detector
stand-by
mode
Flashes
1 time per 1s
after powerup.
Duration up to
60s
During up to
60s
Norm
Not lit
Alarm
Lights up
1 time for 4s
at detection of man
movement in detection
zone (when indication is
enabled)
Relay opens for
4s
Alarm in the
“Alarm
memory”
mode
Figure 4
Relay works in
common mode
Alarm during
test-pass
Lights up
1 time for 2s
at detection of man
movement in detection
zone
Relay opens for
2s
Failure
Keeps lighting until fail-
ure elimination
Relay is open
until failure eli-
mination
relay is open,
relay is closed
Figure 4
7 Operation Modes
Table 2
– Operating modes and settings
Operation mode
Plug name
Jumper position
High detectability
Normal detectability
Sens
+
–
Indication is ON
Indication is OFF
Ind
+
–
“Alarm memory” is ON
“Alarm memory” is OFF
Mem
+
–
TEST-pass
(Switches ON for 8
min.)
Ind
For a short mo-
ment (for 2-3s)
change jumper
position on the
plug
Ind
during
starting of detec-
tor working mode
“+” -
jumper is installed on both plug pins
“-” –
jumper is removed (or installed on one plug pin)
The
“Alarm memory” mode
allows registering the fact
and number of zone violations in prortected area, and is
reflected in corresponding notification .
The mode is activated in 1 minute after installation of
Mem
plug or in 1 min. after starting of detector stand-by mode
with jumper installed previously on
Mem
plug. “Alarm”
notification is indicated in 1 min. after violation of protected
area. To switch the mode off and reset indication, remove
jumper from Mem plug or switch power off.
TEST-pass
allows revealing precise location of sensitive
zones formed by the lens. On expiry of 8 min the detector
automatically starts its stand-by mode.
8 Installation and Pre-starting Procedure
8.1
Works on installation, mounting, maintenance and
operation of detector should be performed only by quaified
persons.
8.2
After transportation in conditions differing from those of
operation keep detector unpacked under supposed operation
conditions for at least 4 hours.
8.3 Selection of Installation Place
8.3.1
Recommended height of installation
8.3.2
In capital buildings it is recommended to install
detector on bearing wall.
8.3.3
In light metalwork buildings one should avoid to install
detector directly on the wall, it is recommended to install
detector on bearing carriers.
8.3.4
Wires of signaling zones and power supply circuits should
be located far from power cables.
8.3.5
It is recommended to close all doors, air-vents, switch
off fans, air-conditioners and other sources of intense air flows
in the room during protection period.
8.3.6
It is not recommended to install detector in the
following places.
m
number of alarm
events (up to 3)
Reiterated indication