IL573 Tek-ENTRY
®
Telephone Entry System Phone-Line Version Manual • 7
Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.
System Installation and Programming
7-digit phone numbers, then change this setting to 10- or 11-digit phone numbers and
program those numbers.
1. When the programming menu displays “7, 10 OR 11 DIGITS?, ” press the “#” key. The
message “TYPE 07, 10 OR 11 DIGITS” will appear.
2. Enter “07” to program 7-digit numbers; enter “10” to program 10-digit numbers; or
enter “11” to program 11-digit numbers. Press the “#” key to save.
3. Press the “*” key to return to the programming menu.
4. If desired, press the “*” key to end program mode.
Pulse or Tone Dialing
This item selects the type of dialing used by the system controller—DTMF (touchtone)
or pulse. Factory default is DTMF. The setting must correspond to the type of telephone
line that has been installed for the entry system.
1. When the programming menu displays “PULSE OR TONE,” press the “#” key. The
message “PULSE OR TONE” will appear.
2. Enter “00” for Pulse (Rotary) dialing; or enter “11” for Tone (DTMF) dialing. Press
the “#” key to save.
3. Press the “*” key to return to the programming menu.
4. If desired, press the “*” key to end program mode.
Door Open Time
The door open time can be reprogrammed to 0-99 seconds to prevent tailgating. Factory
default is 10 seconds. See
Door Timer Cut-Off
in the
System Introduction—Special
Features
section for more information
.
1. When the programming menu displays “DOOR TIME,” press the “#” key. The
message “DOOR OPEN TIME” will appear.
2. Enter a two-digit time in seconds and press the “#” key to save.
3. Press the “*” key to return to the programming menu.
4. If desired, press the “*” key to end program mode.
Talk Time
Talk time can be reprogrammed to 0-99 seconds to set the maximum conversation length
between a visitor and tenant. (Note: Talk time starts when visitor dials tenant.) Factory
default is 60 seconds.
1. When the programming menu displays “TALK TIME,” press the “#” key. The
message “TALK TIME” will appear.
2. Enter a two-digit time in seconds and press the “#” key to save.
3. Press the “*” key to return to the programming menu.
4. If desired, press the “*” key to end program mode.
Night Service (Guard Telephone)
When enabled, the night service on feature redirects all entry system calls to the guard
telephone. Factory default is “disabled.” See
Night Service
in the
System Introduction—
Special Features
section for more information
.
1. When the programming menu displays “NIGHT SERVICE?,” press the “#” key. The
message “ENABLE/DISABLE” will appear.
2. Enter “00” to enable night service; or enter “11” to disable night service. Press the “#”
key to save.
3. Press the “*” key to return to the programming menu.
4. If desired, press the “*” key to end program mode.
Rotary Phones
When rotary phone use is enabled, tenants may use either rotary (pulse) or touchtone
phones with the system. When disabled, tenants may use only touchtone phones. Factory
default is “disabled.”