IL573 Tek-ENTRY
®
Telephone Entry System Phone-Line Version Manual • 3
Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.
Figure 1—System Wiring Diagram (TE903A, TE904, TE905A)
Note:
To battery backup door
release, repeat this section
on T3 and T4 connections.
18 AWG
DOOR STRIKE
120 VAC
120 VAC
DOOR STRIKE
TRANSFORMER MUST BE
COMPATIBLE TO STRIKE
18 AWG 16 VAC
18 AWG
CONNECT DOOR
STRIKE TO D.C. OR A.C.
OUTPUTS. MAXIMUM OUTPUT
IS 28V, 3AMP.
T1
T2
T3
T4
D1
D2
D3
D4
SYSTEM POWER
16 VAC 20 VA
DOOR STRIKE
TRANSFORMER
D.C. (SILENT) +
DOOR STRIKE -
A.C. (BUZZING)
DOOR STRIKE
NO
C
NC
PL
TC
G
FA
ME
AUXILIARY RELAY
MOMENTARY CONTACT
POSTAL LOCK
DOOR TIMER CUTOFF
COMMON
FIRE ALARM INPUT
MULTIPLE ENTRANCE
N.O. SWITCH
N.O. SWITCH
POSTAL LOCK
N.O. CONTACT
FIRE ALARM
MULTIPLE ENTRANCE
TO NEXT TELEPHONE
CONTROLLER SYSTEM.
(G TO G & ME TO ME)
R
T
TO TELEPHONE
JACK
TELEPHONE LINE
PK124
BA001
BA001
Battery Charger
12V Battery
12V Battery
C
B
T1
P
T2
4 AMP FUSE
NOTE: IF USING
BATTERY HOOK-UP,
DO NOT CONNECT
T1 & T2 TO TRANSFORMER
CONNECTIONS
HARDWIRE TO
TO "R" & "T" TERMINALS
OR USE JACK
TO TELEPHONE LINE
-OR-
D1
D0
G
Wiegand Output
Format: 26 bit Wiegand
Voltage: 5 VDC
Open Collector: No
Pulse: 50 uSec. Duration: 1 mSec.