Quick Start Guide

796 Tek Drive, Crystal Lake, IL 60014 USA 

+1 847 857 6076  | +1 847 655 7428 

+1 847 655 6147

www.tek-trol.com

Tek-Flex 4100C

Programmable Two-wire TDR Level Transmitter With Hart & Display

Summary of Contents for Tek-Flex 4100C

Page 1: ...QuickStartGuide 796 Tek Drive Crystal Lake IL 60014 USA 1 847 857 6076 1 847 655 7428 1 847 655 6147 www tek trol com Tek Flex4100C ProgrammableTwo wireTDRLevelTransmitterWithHart Display ...

Page 2: ...try specific installation standards as well as all prevailing safety regulations and accident prevention rules The instrument must only be operated in a technically flawless and reliable condition The operator is responsible for trouble free operation of the instrument During the entire duration of use the user is obliged to determine the compliance of the required occupational safety measures wit...

Page 3: ...ting spirals struts and etc Further more rope or rods must not intersect the filling streams Be cautious during the installation the level of the measured cable medium must not be in the blanking zone the mounting location must keep a min distance to the vessel wall the cable or rod is perpendicular to the surface of the measured medium Note The level of the measured medium must not be in either t...

Page 4: ...stallation with socket if possible otherwise try to minimize the length of socket In case of long stand pipe small vessel or medium with low dielectric constant 1 Wrong The rod rope is in above filling stream which results in the measurement of filling stream not the target medium 2 Correct Note Sun shield or rain proof is suggested for outdoor mounting h d 1 2 ...

Page 5: ...der to avoid damp seal rings used on cables should be screwed tight and the cable must be bended downward outside cable entry as indicated on the diagram below Power supply and current signal are carried by the same two wire connection cable See the Technical Specifi cations of this guide for detailed requirement on power supply 5 Power Supply 1 2 1 2 Wire ...

Page 6: ...value of low flow and output range of current frequency etc OK Keypad Enter programming mode Confirm programming options Confirm modifications to parameters Keypad Modify parameter values Keypad Choose programming options Choose the digit of parameters to edit Display the contents of parameters BK Keypad Programming mode exit Return to higher menu level 6 Adjustment Instructions 0 00 0 10 20 30 40...

Page 7: ...er DC 4100C HART Handheld Programmer 250 ohm Resistance Basic Setting Diagnostics 3 Min adjustment 1 1 Min adjustment 1 2 Medium 1 3 Fast level change 1 4 Damping 1 5 Mapping curve 1 6 Scaled units 1 7 Scaling 1 8 Service 4 Display 2 Linearity consumer programme 1 5 Info 5 Sensor length 1 9 Near blanking 1 10 Sensor tag 1 11 ...

Page 8: ...t Current Distance X zoom Y zoom 1X 2X 5X 10X Unzoom Display value 2 1 LCD contrast 2 2 Peak values 3 1 Meas status 3 2 Choose curve 3 3 Simulation 3 5 Echo curve 3 4 Echo curve 4 1 Current output 4 2 Reset 4 13 Select reset Units of measurement 4 4 Language 4 5 HART operation mode 4 6 Copy sensor Data 4 7 PIN 4 8 Delete Update Create new Sensor type serial number 5 1 Output mode Failure mode Min ...

Page 9: ...Tek Flex4100C Technology Solutions 796 Tek Drive Crystal Lake IL 60014 USA Tel 18478576076 18476557428 Fax 18476556147 Email tektrol tek trol com www tek trol com ...