General
Information
—7A42
MAINFRAME COMPATIBILITY
The
7A42
is
compatible with
all
Tektronix
7000
series
mainframes.
In four-wide
plug-in
compartment
mainframes,
it
can
be
installed
in
either
the
two
leftmost or
two
centermost
plug-in
compartments.
When
used
in
the
two
leftmost
compartments,
select
the
Left
Vertical
Mode
to
display
the
analog
signals.
The
associated
time base
plug-in
Trigger
Source
should
be
Left
Vertical
with
the
time
base
trigger
controls
set
to
Auto
or
Norm,
D
C,
Internal,
Slope
to
+,
with
the
Level
control
centered.
The
A
Then
B
Gate
Output can
be
picked
off
from
the
RIGHT
VERTICAL TRIGGER
SOURCE
by
a
7D11
or 7D15
from either
horizontal
compartment.
In
three-wide
plug-in
compartment
mainframes,
the
7A42
must
be
used
in
the
two
leftmost
compartments
in
a
similar
way.
When
the
7A42
is
installed in
the
center
two
plug-in
compartments
of
a
four
compartment
mainframe;
set
the
mainframe
Vertical
Mode and Trigger Source
to
Right
Vertical.
The
mainframe A Then
B
Gate
Output can not
be
used
in
this
configuration,
however,
the
A Then
B
Gate
is
still
available
at
the
front-panel
TRIGGER
OUT
BNC
connector.
Since
all
analog
channels
are sent out
the
7A42's
left
interface
connector,
it
cannot
use
the
full
capabilities
of
a
dual
beam
oscilloscope
such as
the
7844,
R7844,
and
the
7612D.
However,
it
has
full compatibility
with
these
mainframes
in
a single
beam
configuration.
Since
the
7A42
uses
the
mainframe
CRT
readout
to
display
the
channel
volts
per
division
and error
warning messages, the
7A42
is
not
recommended
for use
in
mainframes
without
readout.
If
the
7A42 is used with
two
time-base
units in a
four
compartment mainframe
where
Chop
has
been
selected
as
the
Horizontal
Mode,
and
if exactly
four
traces
are
to
be
displayed
by
the
7A42,
two
of
the traces
may
synchronize
to
one time
base
while
the
other two
traces
synchronize
to
the
other time base.
To
prevent
this
from
happening,
one
trace
should
be
removed,
or
a
fifth trace
should
be
added to
the
mainframe
ert
display
(even
if
it
is
positioned
off
screen
so
it
cannot
be
seen).
With
one,
two,
three,
or
five traces,
the
channel
display
will
not
synchronize
to
the
horizontal
chop
frequency.
The
7A42
is
compatible with
the
7854
Oscilloscope
mainframe when
the
7854
is
operated
in
real-time.
However,
when
the
7854
is
operated
in
digital
storage,
and
waveform
and
readout
acquisition
is
desired,
the
7A42-7854
mode
should
be
selected,
via
an
internal
jumper;
refer
qualified
service personnel to
the
7A42
Service
manual.
Once
the
7A42-7854
mode
has
been
selected,
proper
readout
and
waveform
acquisition can
be
guaranteed
with the
following
7A42
display
conditions:
1.
Any
single
channel
displayed
alone
(CH1, CH2,
CH3,
CH4,
or TRIG
VIEW).
2.
Channels
1
and
2
only displayed
together, ALT
display
mode
selected.
3.
Channels
3
and
4
only
displayed
together,
ALT
display
mode
selected.
Refer
to
the
Applications
section
in
this
manual
for
further
information.
1-4