Operating
Instructions—7A42
Press
the
NOT pushbutton
51
and notice that
the
CH4
TRIGGER
FUNCTION
indicator
52
is
red
(active
HI).
Press
the
EDGE
pushbutton
53.
Notice
that
the
CH4
TRIGGER
FUNCTION
indicator
52
is
flashing
to
indicate EDGE
qualified
triggering.
Set
the
time-base
Time/Div
to
100
ns
54.
Notice
that
the
TRIG
VIEW
display
has
a
narrow
pulse
55
coincident
with
the
rising
edge
56
of
the
CH4
display.
Press
the
NOT
pushbutton
57.
Observe
that
the
displayed
TRIG
VIEW
pulse
58
now
corresponds
with
the
falling
edge
of
the
CH4
waveform
59.
Adjust
the
pulse
generator
Variable
Duration
control
and
notice that
the
CH4
display
becomes
untriggered
when
the
programmed
trigger
condition
no
longer
exists
(CH1
AND
NOT CH4
EDGE).