background image

MANUAL

 CHANGE

 INFORMATION

At Tektronix, 

we continually strive to keep up with latest electronic 

developments 

by adding circuit and 

component improvements to our 

instruments 

as soon as they 

are

 developed and tested.

Sometimes,

 due to

 printing and shipping requirements, we can’t get these 

changes

 immediately into printed manuals. Hence, your manual may contain new 

change information

 on following pages.

single change may affect several sections. Since the change information sheets 

are

 carried in the manual until all changes are permanently entered, some 

duplication may 

occur. If

 no such change pages appear following this

 page, your 

manual is

 correct as printed.

SERVICE 

NOTE

Because of the universal parts procurement problem, some electrical parts 

in your 

instrument

 may

 

be different from those described in the Replaceable Electrical Parts 

List.

 

The parts

 used will 

in no

 

way alter or compromise the performance or reliability 

of this

 instrument. They are installed when necessary to ensure prompt delivery to 

the customer. 

Order replacement

 parts from the Replaceable Electrical Parts List.

Summary of Contents for 7B53A

Page 1: ...MANUAL SUPPLEMENT TEKTRONIX 7B53A 7B53AN DUAL TIME BASE OPTION 5 INSTRUCTION MANUAL Tektronix Inc 070 1471 00 P O Box 500 Beaverton Oregon 97005 772...

Page 2: ...ect all requests for service or replacement parts to the nearest Tektronix Service Center or Field Office include the type or part number of the product and its serial number Copyright 1972 by Tektron...

Page 3: ...de to P903 or P904 Compatability The TV Sync Separator can be used with 7400 7500 7600 7700 and 7900 Series real time TEKTRONIX oscilloscopes External Graticules External graticules for the main frame...

Page 4: ...less than two fields LINE DISPLAYS 1 Variable Line Selector To obtain Variable Line Selector capabilities the DLY D TRIG control must be set to the RUNS AFTER DLY TIME position Pull the TIME DIV knob...

Page 5: ...e of Q924 The negative pulses will pass through CR918 since during the greater percentage of their duty cycle the line or horizontal sync pulses are positive and will appear to CR918 as positive pulse...

Page 6: ...in a stable display b Adjust the Clipping Level control R914 by rotating the control fully clockwise Then rotate the control counterclockwise until one or more negative going pulses in a group are dis...

Page 7: ...Triggering Amplifier SOURCE switch to TV LINE Adjust the LEVEL control to obtain a triggered display b Rotate the DLY D TRIG control out of the RUNS AFTER DLY TIME position and adjust this control to...

Page 8: ...cer 50 V C932 Add 283 0092 00 0 03 f cer 200 V 80 20 Diodes CR908 Add 152 0075 00 Germanium Tek Spec CR909 Add 152 0141 02 Silicon 1N4152 CR912 Add 152 0141 02 Silicon 1N4152 CR913 Add 152 0141 02 Sil...

Page 9: ...00 150 k 1 4 W 5 R928 Add 315 0822 00 8 2 k 1 4 W 5 R929 Add 315 0123 00 12 k 1 4 W 5 R932 Add 315 0822 00 8 2 k 1 4 W 5 R940 Add 315 0102 00 1 k 1 4 W 5 R941 Add 315 0102 00 1 k 1 4 W 5 S10 Change Sw...

Page 10: ......

Page 11: ...7B53A 7B53AN OPTION 5 TV partial SYNC SEPARATOR TRIGGER PREAMP...

Page 12: ...ince the change information sheets are carried in the manual until all changes are permanently entered some duplication may occur If no such change pages appear following this page your manual is corr...

Page 13: ...ositive and Negative going trigger output signal 50 ns and 1 V High Amplitude output 100 V 0502 01 Comparator output can be alternately chopped to a refer ence voltage SG 503 replaces 190 190A 190B 19...