background image

7B53A/7B53AN 

OPTION 5

SPECIFICATION

General 

Information

The 

TV Sync Separator permits TEKTRONIX real-time 

oscilloscopes

 to display composite video signals. The TV 

Sync 

Separator

 clips video information from the incoming 

video

 signal; then, it amplifies and

 separates the

 field or 

vertical

 trigger pulses from the line or horizontal trigger 

pulses.

 Line rate or field rate trigger pulses are provided 

depending

 

on 

the position of the front panel switch.

This manual insert

 describes the

 special features of the 

7B53A/7B53AN

 OPTION 5 plug-in unit which

 has been 

modified

 to enable

 triggering on

 composite video signals 

through 

the

 use

 of a Sync Separator circuit. The EXT ÷ 10 

and

 LINE positions of the Main Triggering

 Amplifier 

SOURCE

 switch have been replaced by the TV FIELD and 

TV

 LINE

 switch positions, allowing the sweeps to be 

triggered

 

by 

the

 output of the Sync Separator circuit at a 

Field or

 Line Rate.

 The delayed sweep circuit

 has TV 

LINE/EXT

 or INT/EXT SOURCE triggering capability, 

depending 

on 

whether the connection is

 made to P903 or 

P904.

Compatability

The TV Sync

 Separator can

 be used with 7400,

 7500, 

7600,

 7700, and

 7900-Series real time TEKTRONIX 

oscilloscopes.

External

 Graticules

External

 graticules for the main frame are available. Use 

the following information 

when ordering:

Main

 Frame 

External 

Graticule

7403N-7603 

CCIR Composite, Part No.
378-0684-04

NTSC Composite, Part No. 
378-0684-05

Main Frame

 

External

 Graticule

7500,7700,7900 

CCIR Composite, 

Part 

No. 

378-0625-05

NTSC Composite, Part 

No.

378-0625-06

ELECTRICAL

 

CHARACTERISTICS

Connector

Input

 

or Output

 

Signal

COMPOSITE
VIDEO 

IN (2

Major Divisions)

Needs

 2 major

 divisions peak-to- 

peak sync

 negative composite video 

signal.

FIELD

 RATE

A

 group of one to six pulses, whose 

minimum amplitude

 is 2 V nega­

tive, shall

 re-occur at a field rate. 

The

 width of each individual group 

of pulses 

shall not exceed 3H.

LINE

 RATE

The line

 trigger pulses available 

shall have a clean leading edge and a 
minimum

 amplitude of 180 mV 

negative.

SYSTEM

 CHARACTERISTICS

Compatibility

Compatible

 with V and H sync 

signals of standard

 405, 625, 819 

Line/50

 

Hz, and

 525

 Line/60 Hz 

broadcast

 systems;

 405 to 1201 

Line 

closed circuit systems.

Trigger 

Sensitivity

2

 

major divisions or

 more will 

provide

 

stable 

V or H 

triggering.

1

Summary of Contents for 7B53A

Page 1: ...MANUAL SUPPLEMENT TEKTRONIX 7B53A 7B53AN DUAL TIME BASE OPTION 5 INSTRUCTION MANUAL Tektronix Inc 070 1471 00 P O Box 500 Beaverton Oregon 97005 772...

Page 2: ...ect all requests for service or replacement parts to the nearest Tektronix Service Center or Field Office include the type or part number of the product and its serial number Copyright 1972 by Tektron...

Page 3: ...de to P903 or P904 Compatability The TV Sync Separator can be used with 7400 7500 7600 7700 and 7900 Series real time TEKTRONIX oscilloscopes External Graticules External graticules for the main frame...

Page 4: ...less than two fields LINE DISPLAYS 1 Variable Line Selector To obtain Variable Line Selector capabilities the DLY D TRIG control must be set to the RUNS AFTER DLY TIME position Pull the TIME DIV knob...

Page 5: ...e of Q924 The negative pulses will pass through CR918 since during the greater percentage of their duty cycle the line or horizontal sync pulses are positive and will appear to CR918 as positive pulse...

Page 6: ...in a stable display b Adjust the Clipping Level control R914 by rotating the control fully clockwise Then rotate the control counterclockwise until one or more negative going pulses in a group are dis...

Page 7: ...Triggering Amplifier SOURCE switch to TV LINE Adjust the LEVEL control to obtain a triggered display b Rotate the DLY D TRIG control out of the RUNS AFTER DLY TIME position and adjust this control to...

Page 8: ...cer 50 V C932 Add 283 0092 00 0 03 f cer 200 V 80 20 Diodes CR908 Add 152 0075 00 Germanium Tek Spec CR909 Add 152 0141 02 Silicon 1N4152 CR912 Add 152 0141 02 Silicon 1N4152 CR913 Add 152 0141 02 Sil...

Page 9: ...00 150 k 1 4 W 5 R928 Add 315 0822 00 8 2 k 1 4 W 5 R929 Add 315 0123 00 12 k 1 4 W 5 R932 Add 315 0822 00 8 2 k 1 4 W 5 R940 Add 315 0102 00 1 k 1 4 W 5 R941 Add 315 0102 00 1 k 1 4 W 5 S10 Change Sw...

Page 10: ......

Page 11: ...7B53A 7B53AN OPTION 5 TV partial SYNC SEPARATOR TRIGGER PREAMP...

Page 12: ...ince the change information sheets are carried in the manual until all changes are permanently entered some duplication may occur If no such change pages appear following this page your manual is corr...

Page 13: ...ositive and Negative going trigger output signal 50 ns and 1 V High Amplitude output 100 V 0502 01 Comparator output can be alternately chopped to a refer ence voltage SG 503 replaces 190 190A 190B 19...

Reviews: