This section describes

 using

 the TV Sync Separator 

portion 

of

 the time base plug-in unit.

Using

 the TV Sync Separator Plug-In

a.

 

Connect

 a coaxial cable from the oscilloscope vertical 

signal 

input 

connector to a composite video signal source of 

such

 amplitude as to produce

 at least 2 major divisions of 

vertical deflection.

Set 

the

 7B53A/7B53AN OPTION 5 controls as follows:

Main 

Triggering Amplifier

SLOPE

 

MODE

 

COUPLING 
SOURCE

AUTO

DC

TV

 FIELD

TIME/DIV

 

MAG

Main

 

Time Base

2 ms
X1

b.  Set 

the

 oscilloscope

 Main Triggering Amplifier 

SOURCE

 switch to TV 

FIELD and the 

SLOPE switch to —.

c.

  Refer 

to 

the

 information under Obtaining a

 Display 

in this 

section to obtain a display.

Adjusting

 the

 CLIPPING 

LEVEL Control (R914)

NOTE

If

 the

 input

 amplitude of the

 composite video

 

changes,

 

it may be necessary to readjust the CLIP­

PING

 LEVEL 

control (R914).

a.

 

Connect the 

composite

 video as described under the 

heading 

Using 

the TV Sync 

Separator Plug-In.

b.

 

Turn

 the CLIPPING LEVEL control (R914) fully 

clockwise.

c. 

Set

 the oscilloscope controls

 to obtain the desired 

video display.

d.

  Slowly

 

rotate

 the CLIPPING LEVEL control (R914) 

counterclockwise

 until a point is found where the

 most 

stable video 

display results.

TWO

 FIELD DISPLAY

To

 obtain a two field display, adjust the LEVEL control 

to

 obtain a triggered display. The TIME/DIV VARIABLE 

control may

 be adjusted to obtain a display of slightly less 

than two fields.

LINE 

DISPLAYS

1.

 Variable

 Line Selector.

 

To

 obtain Variable Line 

Selector capabilities,

 the DLY'D TRIG control must be set 

to

 the

 RUNS AFTER

 DLY TIME position. Pull the 

TIME/DIV

 knob outward and

 rotate

 the knob to the 

desired 

time/div position (10 µs). Rotate the DELAY TIME 

MULT

 control to the desired portion of the waveform. 

Push 

the

 TIME/DIV knob in and the desired portion of the 

waveform will

 be

 displayed. The delayed sweep is

 free 

running 

in this mode of operation.

2.

 Discrete

 Line Selector. 

For

 Discrete Line Selector 

capability,

 place

 the Delayed Sweep Triggering SOURCE 

switch 

in 

TV LINE 

position. Rotate 

the

 DLY'D TRIG 

control

 out

 of the RUNS AFTER

 DLY TIME position and 

set

 the control to obtain a triggered sweep.

 Rotate the 

DELAY TIME MULT control 

until

 the desired line is 

displayed.

 When rotating the DELAY TIME MULT control, 

the 

display will jump from

 line to line.

3.

  Main

 Triggering Amplifier TV Line. 

Set the TIME/ 

DIV switch

 to 10 µs and

 check

 that the Main Triggering 

Amplifier SOURCE switch

 is set to TV LINE. Adjust the 

LEVEL 

control 

to obtain 

a stable display at the H rate.

Obtaining

 a Display

Install

 

the 

TV Sync

 Separator Plug-In

 in the oscilloscope 

as

 described under

 Using the TV Sync Separator. The 

following

 instructions

 apply for

 the 7B53A/7B53AN OP­

TION 5 plug-in 

unit.

DELAYED INTERNAL 

TRIGGER OPTION

The 

Delayed

 Sweep Triggering SOURCE selection may 

be

 

changed from TV

 LINE/EXT

 to INT/EXT or vice versa. 

For 

INT/EXT triggering 

source capability, move the coaxial 

connector 

from

 P903 to P904 and change the

 pushbutton 

to 

read

 INT/EXT. The pushbutton

 is stored on

 the TV 

Sync

 Separator board.

2

Summary of Contents for 7B53A

Page 1: ...MANUAL SUPPLEMENT TEKTRONIX 7B53A 7B53AN DUAL TIME BASE OPTION 5 INSTRUCTION MANUAL Tektronix Inc 070 1471 00 P O Box 500 Beaverton Oregon 97005 772...

Page 2: ...ect all requests for service or replacement parts to the nearest Tektronix Service Center or Field Office include the type or part number of the product and its serial number Copyright 1972 by Tektron...

Page 3: ...de to P903 or P904 Compatability The TV Sync Separator can be used with 7400 7500 7600 7700 and 7900 Series real time TEKTRONIX oscilloscopes External Graticules External graticules for the main frame...

Page 4: ...less than two fields LINE DISPLAYS 1 Variable Line Selector To obtain Variable Line Selector capabilities the DLY D TRIG control must be set to the RUNS AFTER DLY TIME position Pull the TIME DIV knob...

Page 5: ...e of Q924 The negative pulses will pass through CR918 since during the greater percentage of their duty cycle the line or horizontal sync pulses are positive and will appear to CR918 as positive pulse...

Page 6: ...in a stable display b Adjust the Clipping Level control R914 by rotating the control fully clockwise Then rotate the control counterclockwise until one or more negative going pulses in a group are dis...

Page 7: ...Triggering Amplifier SOURCE switch to TV LINE Adjust the LEVEL control to obtain a triggered display b Rotate the DLY D TRIG control out of the RUNS AFTER DLY TIME position and adjust this control to...

Page 8: ...cer 50 V C932 Add 283 0092 00 0 03 f cer 200 V 80 20 Diodes CR908 Add 152 0075 00 Germanium Tek Spec CR909 Add 152 0141 02 Silicon 1N4152 CR912 Add 152 0141 02 Silicon 1N4152 CR913 Add 152 0141 02 Sil...

Page 9: ...00 150 k 1 4 W 5 R928 Add 315 0822 00 8 2 k 1 4 W 5 R929 Add 315 0123 00 12 k 1 4 W 5 R932 Add 315 0822 00 8 2 k 1 4 W 5 R940 Add 315 0102 00 1 k 1 4 W 5 R941 Add 315 0102 00 1 k 1 4 W 5 S10 Change Sw...

Page 10: ......

Page 11: ...7B53A 7B53AN OPTION 5 TV partial SYNC SEPARATOR TRIGGER PREAMP...

Page 12: ...ince the change information sheets are carried in the manual until all changes are permanently entered some duplication may occur If no such change pages appear following this page your manual is corr...

Page 13: ...ositive and Negative going trigger output signal 50 ns and 1 V High Amplitude output 100 V 0502 01 Comparator output can be alternately chopped to a refer ence voltage SG 503 replaces 190 190A 190B 19...

Reviews: