Basic Test Procedures
3–16
CTS850 SDH/PDH Test Set User Manual
2. Set up the CTS850 as follows:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
TEST SETUPS
RECALL
INSTRUMENT
SETUPS
DEFAULT
FACTORY
SETTINGS
Recall Setup
TRANSMIT
TRANSMIT
SETTINGS
Transmit Rate
STM-1E
Tx/Rx Setup
Coupled
TRANSMIT
POINTERS &
TIMING
Pointer Control
Continuous
RESULTS
SDH RESULTS
none
Defects
3. Press the START/STOP button on the CTS850 so that the
START/STOP light is on.
4. Verify that there are no errors in the SDH RESULTS display.
When the front-panel ERROR light is not on, it also indicates
there are no errors in the received signal.
5. To check for received pointer movements, change the CTS850
setup as follows:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
RESULTS
SDH RESULTS
none
Pointers
6. Verify that the CTS850 is counting positive pointer justifications.
Depending on the clock rate of the NE, some negative pointer
justifications are also possible.