Setting Jitter/Wander Parameters
3–178
CTS850 SDH/PDH Test Set User Manual
Frequency
Amplitude
Highband
Fullband
Wideband
Figure 3–80: Jitter High–Pass Filters
To select the jitter input filter:
Press Menu
Button
Select
Menu Page
Highlight Parame-
ter
Select Choice
RECEIVE
JITTER &
WANDER
Jitter Measurement
Filter
Wideband
Highband
Fullband
H
Select Wideband to measure jitter using the wideband measure-
ment filter (500 Hz – 1.3 MHz).
H
Select Highband to measure jitter using the highband measure-
ment filter (65 kHz – 1.3 MHz).
H
Select Fullband to measure jitter over the wideband range plus
very low frequency jitter that may affect timing quality for Video,
PBX and GSM systems that derive an internal reference from the
supplied line signal (10 Hz – 1.3 MHz).