TB 9-6625-1957-35
12
Figure 2. Tektronix, Type DM 501 A - left side view.
17. Ac Voltage
a. Performance Check
(1) Connect calibrator
OUTPUT
to TI
VOLTS/
Ω
Ω
and
LOW
terminals and press TI
VOLTS AC TRUE RMS
pushbutton.
(2) Press TI range pushbutton and set calibrator output as listed in table 8. TI will
indicate within the specified limits; if not perform adjustments indicated.
NOTE
In the following table, interaction may occur in the
adjustments of R1525 and R1537.
WARNING
In the following table, use an insulated adjustment tool when
adjusting capacitors C1114, C1128 and C1129. The input
potential is connected to the metal top of these capacitors.
b. Adjustments
. No other adjustments can be made.