Safety

Do not touch any object that could provide a current path to the common side of the circuit under 

test or power line (earth) ground. Always make measurements with dry hands while standing on 

a dry, insulated surface capable of withstanding the voltage being measured.
For safety, instruments and accessories must be used in accordance with the operating 

instructions. If the instruments or accessories are used in a manner not speci

 ed in the 

operating instructions, the protection provided by the equipment may be impaired. 
Do not exceed the maximum signal levels of the instruments and accessories. Maximum signal 

levels are de

 ned in the speci

 cations and operating information and shown on the instrument 

panels, test 

 xture panels, and switching cards. 

When fuses are used in a product, replace with the same type and rating for continued 

protection against 

 re hazard. 

Chassis connections must only be used as shield connections for measuring circuits, NOT as 

protective earth (safety ground) connections. 
If you are using a test 

 xture, keep the lid closed while power is applied to the device under test. 

Safe operation requires the use of a lid interlock.
If a        screw is present, connect it to protective earth (safety ground) using the wire 

recommended in the user documentation.

The         symbol on an instrument means warning, risk of electric shock. Use standard safety 

precautions to avoid personal contact with these voltages.

The       symbol indicates a connection terminal to the equipment frame.

The         symbol on an instrument means caution, risk of hazard. The user must refer to the 

operating instructions located in the user documentation in all cases where the symbol is 

marked on the instrument.

The         symbol on an instrument shows that the surface may be hot. Avoid personal contact to 

prevent burns.

If this         symbol is on a product, it indicates that mercury is present in the display lamp. Please 

note that the lamp must be properly disposed of according to federal, state, and local laws.

The 

WARNING

 heading in the user documentation explains hazards that might result 

in personal injury or death. Always read the associated information very carefully before 

performing the indicated procedure.
The 

CAUTION

 heading in the user documentation explains hazards that could damage the 

instrument. Such damage may invalidate the warranty.
The 

CAUTION

 heading with the        symbol in the user documentation explains hazards that 

could result in moderate or minor injury or damage the instrument. Always read the associated 

information very carefully before performing the indicated procedure. Damage to the instrument 

may invalidate the warranty.
Instrumentation and accessories shall not be connected to humans. 
Before performing any maintenance, disconnect the line cord and all test cables. 
To maintain protection from electric shock and 

 re, replacement components in mains circuits 

— including the power transformer, test leads, and input jacks — must be purchased from 

Keithley. Standard fuses with applicable national safety approvals may be used if the rating and 

type are the same. The detachable mains power cord provided with the instrument may only be 

replaced with a similarly rated power cord. Other components that are not safety-related may 

be purchased from other suppliers as long as they are equivalent to the original component 

(note that selected parts should be purchased only through Keithley to maintain accuracy 

and functionality of the product). If you are unsure about the applicability of a replacement 

component, call a Keithley o

  ce for information. 

Unless otherwise noted in product-speci

 c literature, Keithley instruments are designed to 

operate indoors only, in the following environment: Altitude at or below 2,000 m (6,562 ft); 

temperature 0 °C to 50 °C (32 °F to 122 °F); and pollution degree 1 or 2. 
To clean an instrument, use a cloth dampened with deionized water or mild, water-based 

cleaner. Clean the exterior of the instrument only. Do not apply cleaner directly to the instrument 

or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with 

no case or chassis (e.g., a data acquisition board for installation into a computer) should never 

require cleaning if handled according to instructions. If the board becomes contaminated and 

operation is a

 ected, the board should be returned to the factory for proper cleaning/servicing. 

Safety precaution revision as of June 2017.

Summary of Contents for Keithley 3700A Series

Page 1: ...Series 3700A System Switch Multimeter Quick Start Guide...

Page 2: ...r high transient overvoltages often associated with local AC mains connections Certain Keithley measuring instruments may be connected to mains These instruments will be marked as category II or highe...

Page 3: ...the associated information very carefully before performing the indicated procedure The CAUTION heading in the user documentation explains hazards that coulddamage the instrument Such damage may inva...

Page 4: ...sea level Operating temperature 0 C to 50 C up to 80 relative humidity at 35 C Storage temperature 40 C to 70 C Pollution degree 1 or 2 CAUTION Carefully consider and configure the appropriate output...

Page 5: ...lot system switch with high performance DMM 3706A S six slot system switch without DMM 3706A SNFP six slot system switch without DMM and without front panel display and keypad Complete documentation f...

Page 6: ...com keithley You can search for the specific software you need Available software includes Keithley KickStart Instrument Control Software Lets you start making measurements in minutes without complex...

Page 7: ...e the packaging insert Packaging insert 4 Remove the bag that contains the documentation and accessories 5 Carefully lift the instrument out of the box 6 Inspect the instrument for any obvious signs o...

Page 8: ...3706A SNFP six slot system switch without DMM and front panel display and keypad You receive the 3700A with these accessories and documents 1 Power line cord 2 RJ 45 LAN crossover cable Series 3700A...

Page 9: ...n the system For example if you are using a 500 V power supply with a 300 V dc rated switch the maximum allowed voltage in the system is 300 V dc Cover the device under test DUT to protect the operato...

Page 10: ...port the following cards Model 3720 Dual 1 30 Multiplexer Card automatic CJC with 3720 ST accessory Model 3721 Dual 1 20 Multiplexer Card automatic CJC with 3721 ST accessory Model 3722 Dual 1 48 High...

Page 11: ...ced users disconnect DUT and external circuitry from switching cards This allows you to exercise safe close open operations without the dangers associated with live test circuits WARNING Slot covers m...

Page 12: ...odule there is a mounting screw Use the flat bladed screwdriver to tighten these two screws to secure the module to the mainframe Do not overtighten 8 Reconnect the power line cable and any other cabl...

Page 13: ...the operating voltage in your area is compatible CAUTION Operating the instrument on an incorrect line voltage may cause damage to the instrument possibly voiding the warranty WARNING The power cord...

Page 14: ...er module on the rear panel Connect power cord 3 Connect the plug of the power cord to a grounded ac outlet Turn on the instrument Turn on the instrument by pressing the front panel POWER switch to th...

Page 15: ...luminate then all three indicator lights illuminate briefly Test the instrument For instruments with a front panel display the Models 3706A and 3706A S you can view system information to check operati...

Page 16: ...I turn the instrument on If an error message is displayed press the EXIT LOCAL key The Series 3700A instrument returns to the default display screen For detailed information about error messages see...

Page 17: ...vides detailed applications to help you scan read write and control channels The examples in the Application Manual demonstrate increasing levels of Series 3700A functionality For detailed information...

Page 18: ...y U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specfication and price change privileges reserved TEKTRONIX and TEK ar...

Reviews: