Commands listed in alphabetical order
Arguments
Examples
MEASUrement:MEAS<x>:SSC:NOMinalfreq
This command sets or queries the user-de
fi
ned frequency for the measurement
when the measurement type is SSC. The measurement number is speci
fi
ed by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:SSC:NOMinalfreq <NR3>
MEASUrement:MEAS<x>:SSC:NOMinalfreq?
Arguments
<NR3>
is the user-de
fi
ned nominal frequency type for SSC con
fi
gurations.
Examples
MEASUrement:MEAS1:SSC:NOMinalfreq 2.0E+
9 sets the frequency to 2.0
GHz.
MEASUrement:MEAS1:SSC:NOMinalfreq?
might return
:MEASUREMENT:MEAS1:SSC:NOMINALFREQ 2.5000E+9
indicating
the frequency is 2.5 GH.
MEASUrement:MEAS<x>:SSC:NOMinalfreq:SELECTIONtype
This command sets or queries the frequency detection type for the measurement
when the measurement type is SSC. The measurement number is speci
fi
ed by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:SSC:NOMinalfreq:SELECTIONtype
{AUTO|MANual}
MEASUrement:MEAS<x>:SSC:NOMinalfreq:SELECTIONtype?
Arguments
AUTO
automatically sets the detection type.
MANual
speci
fi
es the manual detection type.
Examples
MEASUrement:MEAS1:SSC:NOMinalfreq:SELECTIONtype AUTO
speci
fi
es
the auto-detection type.
2-486
MSO54, MSO56, MSO58, MSO58LP Programmer
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...