Command groups
Table 2-31: Measurement commands (cont.)
Command
Description
MEASUrement:CH<x>:REFLevels:ABSolute:
FALLMid
This command sets or queries the value used as the mid reference level of the falling
edge when the source ref level method is set to absolute.
MEASUrement:CH<x>:REFLevels:ABSolute:
HYSTeresis
This command sets or queries the value of the hysteresis of the reference level when
the source ref level method is set to absolute.
MEASUrement:CH<x>:REFLevels:ABSolute:
RISEHigh
This command sets or queries the value used as the high reference level of the rising
edge when the source ref level method is set to absolute.
MEASUrement:CH<x>:REFLevels:ABSolute:
RISELow
This command sets or queries the value used as the low reference level of the rising
edge when the source ref level method is set to absolute.
MEASUrement:CH<x>:REFLevels:ABSolute:
RISEMid
This command sets or queries the value used as the mid reference level of the rising
edge when the source ref level method is set to absolute.
MEASUrement:CH<x>:REFLevels:ABSolute:
TYPE
This command sets or queries the reference level type for the source.
MEASUrement:CH<x>:REFLevels:BASETop
This command sets or queries the method used to calculate the TOP and BASE, used
to calculate reference levels for the measurement.
MEASUrement:CH<x>:REFLevels:METHod
This command sets or queries the method used to calculate reference levels for
the source.
MEASUrement:CH<x>:REFLevels:PERCent:
FALLHigh
This command sets or queries the percentage (where 100% is equal to TOP and 0%
is equal to BASE) used to calculate the high reference level of the falling edge when
the source ref level method is set to percent.
MEASUrement:CH<x>:REFLevels:PERCent:
FALLLow
This command sets or queries the percentage (where 100% is equal to TOP and 0%
is equal to BASE) used to calculate the mid reference level of the falling edge when
the source ref level method is set to percent.
MEASUrement:CH<x>:REFLevels:PERCent:
FALLMid
This command sets or queries the percentage (where 100% is equal to TOP and 0%
is equal to BASE) used to calculate the mid reference level of the falling edge when
the source ref level method is set to percent.
MEASUrement:CH<x>:REFLevels:PERCent:
HYSTeresis
This command sets or queries the percentage (where 100% is equal to MAX and 0%
is equal to MIN) used to calculate the hysteresis of the reference level when the
source ref level method is set to percent.
MEASUrement:CH<x>:REFLevels:PERCent:
RISEHigh
This command sets or queries the percentage (where 100% is equal to TOP and 0%
is equal to BASE) used to calculate the high reference level of the rising edge when
the source ref level method is set to percent.
MEASUrement:CH<x>:REFLevels:PERCent:
RISELow
This command sets or queries the percentage (where 100% is equal to TOP and 0%
is equal to BASE) used to calculate the low reference level of the rising edge when the
source ref level method is set to percent.
MEASUrement:CH<x>:REFLevels:PERCent:
RISEMid
This command sets or queries the percentage (where 100% is equal to TOP and 0%
is equal to BASE) used to calculate the mid reference level of the rising edge when
the source ref level method is set to percent.
MEASUrement:CH<x>:REFLevels:PERCent:
TYPE
This command speci
fi
es or queries the reference level percent type for the source.
2-40
MSO54, MSO56, MSO58, MSO58LP Programmer
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Page 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...