Commands listed in alphabetical order
outside the upper and lower thresholds for longer than the time limit
(
:TRIGger:{A|B}:WINdow:WIDTH
) without crossing through either the upper
or lower threshold.
Examples
TRIGger:A:WINdow:CROSSIng LOWER
sets crossing to lower.
TRIGger:A:WINdow:CROSSIng?
might return
:TRIGGER:A:WINDOW:CROSSING UPPER
indicating the crossing is set to upper.
TRIGger:{A|B}:WINdow:LOGICQUALi
fi
cation
This command speci
fi
es whether or not to use logic quali
fi
cation for a window
trigger.
Group
Trigger
Syntax
TRIGger:{A|B}:WINdow:LOGICQUALification {ON|OFF}
TRIGger:{A|B}:WINdow:LOGICQUALification?
Arguments
ON
speci
fi
es that the window trigger type uses logic quali
fi
cation.
OFF
speci
fi
es that the window trigger type does not use logic quali
fi
cation.
Examples
TRIGger:A:WINdow:LOGICQUALification ON
turns on logic quali
fi
cation.
TRIGger:A:WINdow:LOGICQUALification?
might return
:TRIGGER:A:WINDOW:LOGICQUALIFICATION OFF
indicating logic
quali
fi
cation is off.?
TRIGger:{A|B}:WINdow:SOUrce
This command sets or queries the source for a window trigger.
NOTE.
Digital channels are not supported as window trigger sources.
Group
Trigger
Syntax
TRIGger:{A|B}:WINdow:SOUrce {CH<x>}
TRIGger:{A|B}:WINdow:SOUrce?
MSO54, MSO56, MSO58, MSO58LP Programmer
2-873
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Page 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...