Commands listed in alphabetical order
MEASUrement:REFLevels:ABSolute:HYSTeresis
This command sets or queries the value of the hysteresis of the reference level
when the measurement's ref level method is set to absolute.
Group
Measurement
Syntax
MEASUrement:REFLevels:ABSolute:HYSTeresis
<NR3>
MEASUrement:REFLevels:ABSolute:HYSTeresis?
Arguments
<NR3>
is the value of the hysteresis of the reference level.
Examples
MEASUrement:REFLevels:ABSolute:HYSTeresis 20.0E-3
sets the
hysteresis to 20.0 mV.
MEASUrement:REFLevels:ABSolute:HYSTeresis?
might return
:MEASUREMENT:REFLEVELS:ABSOLUTE:HYSTERESIS 30.0000E-3
indicating the hysteresis is set to 30.0 mV.
MEASUrement:REFLevels:ABSolute:RISEHigh
This command sets or queries the value used as the high reference level of the
rising edge when the measurement's ref level method is set to absolute.
Group
Measurement
Syntax
MEASUrement:REFLevels:ABSolute:RISEHigh
<NR3>
MEASUrement:REFLevels:ABSolute:RISEHigh?
Arguments
<NR3>
is the value used as the high reference level of the rising edge.
Examples
MEASUrement:REFLevels:ABSolute:RISEHigh 1.5
sets the high reference
to 1.5 V.
MEASUrement:REFLevels:ABSolute:RISEHigh?
might return
:MEASUREMENT:REFLEVELS:ABSOLUTE:RISEHIGH 1.0000
indicating the
high reference is 1.0 V.
2-498
MSO54, MSO56, MSO58, MSO58LP Programmer
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Page 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...