Operating Basics
This section provides the basic operating information for each component of
the RFM220 system:
RFM220 instrument
RFM220 Aggregator application
RFM220 Client application
RFM220 Device Setup utility
RFM220 Instrument
Installation
Considerations
Network installation.
If you are operating the RFM220 system on a local
Ethernet network, the RFM220 instrument(s) to be monitored must be
connected to the same network as the PC or server hosting the RFM220
Aggregator application.
Non-network installation.
If you are operating the RFM220 system without an
Ethernet network, you must directly connect the Ethernet port on the RFM220
instrument to the Ethernet port on the PC or server hosting the RFM220
Aggregator and Client applications.
Network Settings
The RFM220 instrument is shipped with a default IP address (192.168.0.209).
Use the RFM220 Device Setup utility to change the network settings of a
RFM220 instrument so that it can operate on your network.
guring the Network Settings of a RFM220 Instrument
If you lose or cannot remember the IP address of a RFM220 instrument,
you can recover the IP address using an RS-232 command. (See page 77,
RFM220 User Manual
41
Summary of Contents for RFM220
Page 1: ...xx RFM220 ISDB Tb Measurement Demodulator ZZZ User Manual P071289600 071 2896 00...
Page 2: ......
Page 10: ......
Page 22: ...Compliance Information xii RFM220 User Manual...
Page 26: ...Preface xvi RFM220 User Manual...