Performance Verification and Adjustment Procedures
4–24
TSG 95 Service Manual
Adjustment Procedures
Remove the TSG 95 back cover before proceeding; see the instructions on page
5–12. Power the instrument with the AC adapter while making adjustments.
1. Adjust LCD Contrast
a. Press the Lock Out button, to make sure that the LCD backlight is on.
b. ADJUST — LCD Contrast, R1, counterclockwise until the unused LCD
segment rectangles appear, then adjust R1 clockwise until they just dis-
appear. Stop adjusting R1 before the intensity of the displayed LCD
characters is affected.
2. Adjust Subcarrier Frequency
a. Connect the TSG 95 Video Output to the PAL/NTSC test signal genera-
tor genlock input with a 75
Ω
coaxial cable. Terminate the genlock input
in 75
Ω
, if necessary.
b. Connect the PAL/NTSC test signal generator subcarrier output to the
frequency counter A input, using a 75
Ω
coaxial cable.
c.
Connect a reference, such as WWV, to the B input of the frequency
counter.
d. Set the frequency counter for a ratio of A/B, and set the AVG to 106.
e.
ONLY IF NECESSARY, remove the tape cover from the adjustment
hole on the oscillator, Y1.
f.
ADJUST — the subcarrier frequency to 3.579545 MHz
±
0.5 Hz
(NTSC) or 4.43361875 MHz
±
0.5 Hz (PAL).
NOTE
. The subcarrier frequency specification is
±
10 Hz, but it is recommended
that this adjustment be made as close to the “exact” frequency as possible to
maximize performance.
The crystal may drift after adjustment. Leave the Pathfinder powered up for 20
minutes after adjustment, then check the frequency a second time to verify that it
has remained within spec.
g. Reinstall the tape cover on the oscillator.
3. Adjust PAL DC Gain and Blanking Level
a. Connect the TSG 95 Video output to the VM700A Channel A Input and
terminate the loopthrough in 75
Ω.
b. Select the PAL Matrix signal from the Pathfinder (press R).
Summary of Contents for TSG 95
Page 4: ......
Page 6: ...TSG 95 Service Manual...
Page 14: ...Service Safety Summary viii TSG 95 Service Manual...
Page 30: ...Specifications 1 16 TSG 95 Service Manual Figure 1 5 PAL Green Field Figure 1 6 PAL Blue Field...
Page 35: ...Specifications TSG 95 Service Manual 1 21 Figure 1 15 PAL Reduced Sweep Figure 1 16 PAL Pluge...
Page 40: ...Specifications 1 26 TSG 95 Service Manual Figure 1 25 PAL Matrix Signal UK ITS 2...
Page 41: ...Specifications TSG 95 Service Manual 1 27 Figure 1 26 PAL Safe Area...
Page 43: ...Specifications TSG 95 Service Manual 1 29 Figure 1 28 SMPTE NTSC Color Bars Zero Setup...
Page 50: ...Specifications 1 36 TSG 95 Service Manual Figure 1 41 NTSC Convergence Components...
Page 53: ...Specifications TSG 95 Service Manual 1 39 Figure 1 46 NTSC Cable Sweep Figure 1 47 NTSC Matrix...
Page 54: ...Specifications 1 40 TSG 95 Service Manual Figure 1 48 NTSC Safe Area...
Page 104: ...Performance Verification and Adjustment Procedures 4 30 TSG 95 Service Manual...
Page 118: ...Maintenance 5 14 TSG 95 Service Manual...
Page 134: ...TSG 95 Service Manual 7 8...
Page 139: ...Replaceable Mechanical Parts 8 5 TSG 95 Service Manual A1 A2 A3 Figure 1 Exploded View...
Page 140: ...Replaceable Mechanical Parts 8 6 TSG 95 Service Manual...