www.tekvox.com
1201-N+
79033-N+ User Manual
5.6.2 RS232 Control Modes
There are two RS232 operational control modes for the TEK 1201-N+ to function with. One allows a
3rd party control system to operate the TEK 1201-N+ using the local RS232 port on the unit, while also
allowing the control system to send RS232 commands to a display via the RS232 on the HDBaseT
receiver. The other (TekMonitor serial control) allows the TEK 1201-N+ to be controlled from both the
local RS232 port on both the unit and the HDBaseT receiver.
5.6.3 Control TEK-1201-N+ AND Display from Local RS232 Port
This mode allows a 3rd party controller to send commands to both the TEK 1201-N+ and display
device.
1)
Connect the RS232 port of TEK 1201-N+ to RS232 port of PC.
2)
Send the command 50787% via RS232 communication software.
3)
Send the right command of TEK 1201-N+ or other remote RS232 device connected in present
system. Connection is shown below:
Control 1201-N+ and Display from Local