Installing the GW-483S
This section contains instructions for the indoor/outdoor installation of the GW-483S system. The
installation is broken into three distinct phases:
1.
2.
Installing the VoIP Gateway Board Enclosure
3.
Installing the RF Video Board (Optional)
After completing the installation, you can refer to:
•
The
GW-483S User Guide
(MN100112) in order to configure the system.
•
The
section for information on system LEDs and problem isolation.
Installing the Cabinet
This section describes the mounting of the cabinet and its connection to the service provider’s fiber
optic cable.
Mounting the Cabinet
The cabinet must be mounted on either an indoor or an outdoor wall. The mounting location should
have an even surface and should be easily accessible by subscribers or service personnel.
NOTE
The mounting wall must be at 90 degree angle to the ground. The cabinet must
be situated with all openings facing down.
NOTE
When installing the cabinet outdoors, choose a location that is away from
down spouts and water sprinklers.
To install the cabinet:
1.
Ensure that the mounting surface is even. To prevent cabinet warpage, use
washers as shims to correct any surface unevenness.
2.
With the cabinet in the closed position, attach the top of the cabinet to the
wall using the upper mounting ear.
3.
Open the main cover and then fasten the bottom of the cabinet to the wall
using the exposed lower mounting ear.
Service Provider Fiber Optic Cable Connection
1.
Remove the large black rubber grommet located at the bottom left side of
the cabinet (see
Installing the GW-483S
12