P R O T O C O L H . 3 2 3 C O N F I G U R A T I O N
Rev H
135 of 244
1. In the vertical menu bar of the current VoIP Gateway Web page, select
CODECS
. The
Audio/CODEC Configuration page appears (
The VoIP Gateway supports G711 u-law and a-law standards by default. The user can set
the VoIP Gateway to also support one of the three voice coding standards: G723, G726 or
G729. Up to two ports will be allowed to use the selected option. The remaining ports (if
any) will support G711 u-law and a-law. For every supported voice coding standard the
user can enable/disable
Silence Suppression
and, except for G723, select the default
Packetization
period (as a multiple of 10ms in the range 10ms-100ms).
Figure 13-3 Audio/CODEC Configuration Page
The VoIP Gateway supports G711 u-law and a-law standards by default. The user can set the
VoIP Gateway to also support one of the three voice coding standards: G723, G726 or G729.
Up to two ports will be allowed to use the selected option. The remaining ports (if any) will
support G711 u-law and a-law. For every supported voice coding standard the user can
enable/disable
Silence Suppression
and, except for G723, select the default
Packetization
period (as a multiple of 10ms in the range 10ms-100ms).
NOTE
Only one complex code (G723, G726, G729) can be selected.
2.
Select the Audio/CODEC
standard
.
3.
Set the
Packetization
period.
Summary of Contents for AC - 232 - TX
Page 4: ......
Page 24: ......
Page 44: ......
Page 50: ......
Page 68: ......
Page 79: ...C L I C O M M A N D M O D E S Rev H 79 of 244 Figure 9 4 Network Mode show and set Commands ...
Page 81: ...C L I C O M M A N D M O D E S Rev H 81 of 244 Figure 9 8 SIP Mode show and set Commands ...
Page 98: ......
Page 108: ......
Page 156: ......
Page 158: ......
Page 170: ......
Page 184: ......
Page 202: ......
Page 228: ......
Page 234: ......
Page 242: ......