GW-482S INSTALL ATION GUID E
14
MN100143 Rev B
Installation Instructions for Unit Supplied With Patch Panel
Required Equipment
•
Type-110 insertion tool
•
Screwdriver
•
Recommended cables:
For 10/100BaseT X LAN ports connections, use shielded twisted pair 100 Ohm CAT
5, also called STP CAT 5 with a solid wire.
For phone connections, use standard telephone with solid wires
Connecting the Ethernet and DTMF Phone Cables
•
The user must connect the data and v oice communication cables to the
LAN and Phone connectors on the Patch Panel using a Type-110 insertion
tool).
•
For 10/100BaseTX ports, use shielded tw isted pair 100 Ohm CAT 5 or STP
CAT 5 w ith solid wire.
•
For phones, use standard DTMF telephone cables.
1. Push up to eight (8) 10/100BaseTX wires and the phone wires through the ingress at the
bottom of the unit. Push the cables in, one at a time, through the small opening in the center of
the rubber seal.
Figure 17: The LAN port and Phone Connectors on the Patch Panel
2.
Use the Type-110 insertion tool to connect the Ethernet wires to
L1
-
L8
connectors on the
Patch Panel
as shown in the following table
(notice that the wires and connectors are
color coded):
LAN
Connections
Voice
Connections
Ingress